Special Calibration (cont.)
Special Calibration Settings - Page 1
1 2 3 4
1
2
3
4
TANK FILL LEVEL
TANK ALARM LEVEL
START SPEED TIME
START SPEED
Setting Locations
Page
Page
UNITS
Location:
PAGE 1 - AREA
Description:
Defines unit of measurement - English,
Metric - and loads system defaults. Changing UNITS
setting also clears all counters.
Default:
English
CONTROL SPEED
Location:
PAGE 1 - DISTANCE
Description:
(OPTIONAL)
This position adjusts valve response
time to fine-tune the system. Example: increase Control Speed
if the system is responding slowly to rate changes because of
slow-moving valves. The range of settings is -12 to 3.
NOTE: Exercise caution when increasing the valve response
speed - the system may become unstable with higher
control speed numbers entered.
Default:
-1
OUTPUT TYPE - PWM OR STD
Location:
PAGE 1 - PRESSURE
Description:
Choose PULSE (PWM) OR STD (reversing
polarity DC) electronic drive signal for the control
valve. The display will show
PULSE
or
Std
(also
shown when console is powered up.)
Default:
Standard DC
Hold Input Polarity -
NOT USED
Location:
PAGE 1 - SPEED
Description:
This setting is NOT used in this version of the
SprayMate XRS. Do Not Adjust.
Default:
Closed
UNITS
CONTROL SPEED
OUTPUT TYPE - PWM or STD
Hold Input Polarity (NOT USED)
START SPEED
Location:
PAGE 1 - RATE
Description:
Enables “Quick Start - Speed” function and
defines the intended simulated speed in MPH (km/H).
See Appendix C for details. Setting to 0 (Off) will
disable the function.
Default:
Off
START SPEED TIME
Location:
PAGE 1 - TANK
Description:
Enables “Quick Start - Speed” function and
defines the duration of the simulated speed - up to 6
seconds. See Appendix C for details. Setting to 0 (Off)
will disable the function.
Default:
Off
TANK ALARM LEVEL
Location:
PAGE 1 - VOLUME/MINUTE
Description:
Enables and adjusts value for Tank Alarm -
set value to notify operator when level is reached. This
can be set to OFF (0) or between 1 - 65535.
Parameter units: English = gallons, Metric = liters.
Default:
Off
TANK FILL LEVEL
Location:
PAGE 1 - VOLUME
Description:
Adjust this setting to the known capacity
of the tank. This value will be automatically entered
when in Tank position by pressing the Increase (+)
button. This can be set to OFF (0) up to 65535 max.
Parameter units:
English - gallons
Metric - liters
Default:
Off