Special Calibration
Page 4
Page 3
Page 2
Page 1
Minimum
Alarm Speed
Minimum
Pressure
Manual
Enable
Tank Fill
Level
Audible Alarm
Enable
Fixed
Minimum
Flow
Three-way
Valve
Enable
Tank Alarm
Level
Section Input
Polarity
Proportional
Minimum
Flow
Auto Shutoff
Start Speed
Time
—
Rate Alarm
Threshold
Start Speed
Page 1
Page 2
Page 3
Page 4
Units
Pressure Offset
PWM
Frequency
Multifunction
Output Flow
Trigger Threshold
Control Speed
Pressure Alarm
Low
Maximum
Pulse Width
Multifunction
Output
Output Type
PWM or STD
Pressure Alarm
High
Minimum
Pulse Width
Flush Delay
Time
Hold Input
Polarity
Pressure
Full Scale
—
Flush Time
The UNITS position must be set before changing any other Calibration or Special Calibration settings.
These settings enable or disable other setting options to adjust applicable parameters:
• UNITS
: determines which unit of measurement is used
• OUTPUT TYPE
- PWM or STD: defines electronic drive signal for the control valve
• MULTIFUNCTION
: defines MULTIFUNCTION output configuration
Special Calibration settings are accessed by selecting the parameter with the main rotary knob and then pressing the CAL
button to access Pages. Numbers displayed on the screen indicate which Page is active. Pressing the AUTO/MAN button once
displays an abbreviated parameter title.
See
next page 15
for descriptions of Special Calibration settings.
Note:
Changing
UNITS
will load default CAL values and reset all counters to 0.
Agitation %
Valve Polarity
STD
STD
STD = Standard 12V operation only
PWM
PWM
PWM
PWM
PWM = PWM operation only
Left Side of Rotary Dial
Right Side of Rotary Dial
SPECIAL CALIBRATION STEPS:
1.
Turn ON console while pressing the CAL button - screen will display “SPEC”, then ‘CAL” and number 1 (Page 1).
2.
Select a Special Calibration position using rotary knob. (See explanations of settings starting below)
3.
Adjust Page 1 value or press the CAL button to access Pages 2-4.
4.
Adjust parameter using Increase/Decrease buttons.
5.
To exit Special Calibration without saving changes - turn console OFF.
6.
To save changes and exit Special Calibration - press and hold the CAL button for 1 second - ‘CAL’ icon on screen
will turn off and red LED light will turn off.