background image

spEEd  CAL  FOR  RAdAR  OR  Gps  spEEd  sENsORs:

  

See the following table for SPEED CAl numbers to enter for 

various radar models or GPS speed sensors.  

To fine tune the 

spEEd CAL number, see Appendix b on page 44.

WIDTH

CAL

FLOW

CAL

MIn

FLOW

ADJUST

rATE

TArGET

rATE

SPEED

CAL

InLInE

BYPASS

TEST

SPEED

VOLUME /

MInUTE

DISTAnCE

ArEA /

HOUr

VOLUME

(1) (2) (3)

rATE

SPEED

ArEA

(1) (2) (3)

On

OFF

1

2

3

4

5

B O O M S

rUn

HOLD

CAL

AUTO

MAn

rESET

On / OFF

____

APPLICATIOn rATE

TAnK

___

MAnAUTO

CAL HOLD

Illustration 14

spEEd  CAL:

    This  position  is  used  to  calibrate  the  speed 

sensor for ac cu rate speed and dis tance measurement. When 

this position is selected, 

the  display  will  show 

the  SPEED   CAl  value 

along with “CAl” on the 

display.  

See Illustration 

14.

  In English units, the 

SPEED CAl  number  is 

displayed in inches, in metric it is displayed in centimeters.

SPEED

CAL

DISTAnCE

INLINE/bypAss:

      The  display  will  show  inLinE  or  bYPASS.  

use  the  “+”  or  “-”  buttons  to  toggle  to  desired  selection.  

Inline is used when the servo is in the line going out to the 

booms;  Bypass  is  used 

when  the  servo  is  in  a 

return  line.   

NOTE:  if 

used  on  a  Micro-Trak 

NH3 system, it must be 

set to bypass.

InLInE

BYPASS

ArEA /

HOUr

Radar or Gps speed sensor Calibration

Radars

English Cal # in. Metric Cal # in.

Hz/MPH

Vansco

.150

.38

58.90

Raven

.148

.38

59.80

Magnavox

.154

.39

57.40

 Dickey-john

 (NOTE:  Dickey-john

 radars may be factory

 calibrated for any of

 these four settings).

.149

.38

58.94

.199

.51

44.21

.319

.81

27.64

.518

1.32

17.034

GPS Speed

Astro II & 5

.189

.48

46.56

SkyTrak (Std)

.150

.38

58.94

SkyTrak (MT)

.910

2.31

9.82

Dickey-john

.210

.53

42.00

John Deere

 (In-cab speed signal)

.197

.50

44.70

6

Calibration

 (cont)

Entering Calibration Values 

(cont)

Summary of Contents for MT-3405 F II

Page 1: ...MT 3405F II Dual Display automatic rate controller Operation and Calibration Reference Manual...

Page 2: ...adar or GPS Speed Sensor Calibration 6 Determining the Speed Cal 7 Drive Shaft Speed Sensor Calibration 7 Test Speed 7 Exiting Calibration 7 Factory loaded Calibration Values 7 Special Calibration 8 9...

Page 3: ...m automatic control to manual CAL This key is used to enter exit the calibration mode Key Functions PROGRAM KEYS Used to increment and decrement the different calibration values RESET when not in CAL...

Page 4: ...hold the CAL key until CAL icon appears on the display The con sole is now in cal i bra tion and Metric mode is selected Exit CAL by pressing and holding the CAL key until CAL disappears from the dis...

Page 5: ...um rate for the nozzles The minimum flow rate in gallons per minute li ters per minute based on the nozzles being used for the en tire boom on the sprayer DO NOT enter the actual flow of your spray ap...

Page 6: ...glish units the SPEED CAL number is displayed in inches in metric it is displayed in centimeters SPEED CAL DISTAnCE INLINE BYPASS The display will show InLinE or bYPASS Use the or buttons to toggle to...

Page 7: ...ra tion process exit calibration by pressing and holding the CAL button until the RED warning light turns off one sec ond Basic cal i bra tion is now com plete BEFORE beginning application confirm tha...

Page 8: ...ze volume of Full Tank Off or 1 65 535 Off Tank Low Set Point Sets Alarm Set Point if using TANK Function Off or 1 65 535 Off Auto Shut off Runs Servo Toward Minimum when in Hold On Off Off Auto Delay...

Page 9: ...aution when increasing the valveresponsespeed Ifusing a relatively fast valve 1 3 seconds open to close the system may become unstable with higher valve response speed numbers entered TEST SPEED SPEED...

Page 10: ...he console is in HOLD or if all Boom Valves are OFF the and buttons will not control the servo valve unless the rotary switch is in the VOLUME MINUTE position In that position only the servo valve can...

Page 11: ...AUTO FILL feature is active this feature allows the TANK counter to be quickly reset to a full tank amount by simply pressing the button with the rotary switch in the TANK position The button can be...

Page 12: ...ues to hold the button for 1 second CLEAr will disappear and be replaced by 0 indicating that the selected pair of counters has been cleared Clearing Counters When the desired counter number is displa...

Page 13: ...NOTES 13...

Page 14: ...A N U F A C T U R E D I N U S A BY 111 E LeRay Avenue P O Box 99 Eagle Lake MN 56024 0099 Toll Free 800 328 9613 507 257 3600 Fax 507 257 3001 www micro trak com trakmail micro trak com 2007 Micro Tr...

Reviews: