resetting System Counters
WIDTH
CAL
FLOW
CAL
MIn
FLOW
ADJUST
rATE
TArGET
rATE
SPEED
CAL
InLInE
BYPASS
TEST
SPEED
VOLUME /
MInUTE
DISTAnCE
ArEA /
HOUr
VOLUME
(1) (2) (3)
rATE
SPEED
ArEA
(1) (2) (3)
On
OFF
1
2
3
4
5
B O O M S
rUn
HOLD
CAL
AUTO
MAn
rESET
On / OFF
____
APPLICATIOn rATE
TAnK
___
AUTO
The AREA, DISTANCE and VOluME counters maintain a
running count during operation regardless of the position
of the rotary switch. When any of these counters reach their
maximum capacity, or when you want to start a new count,
the value may be reset to zero by performing the following
routine. Counter pairs may be reset independently of other
counter pairs.
Turn the booms OFF or put the system in HOlD.
1.
Turn the rotary switch to the counter to be reset.
2.
To reset distance turn the rotary switch to DISTANCE and
3.
simply press and hold the RESET button until the display
reads zero. The display will show the word “ClEAr”
during this process, and will show 0.0 when reset to zero
is complete.
To reset the volume and area counters; there are three
4.
independent AREA counters, paired with three VOluME
counters. The active pair of counters is indicated by the
small numbers in the lower right area of the display (1,2,
or 3) when the rotary switch is in the AREA or VOluME
position. Select the pair of counters you want to use by
pressing the “+” button. The small number will increment
each time the “+” button is pressed (from 1 to 3, then
rolls back to 1). DO NOT attempt to select the counter
number by using the “-” button, because that will clear
the active pair of counters if held for 1 second. If the “-”
button is accidentally pressed, the console will display
“ClEAr” to alert the user that the counters will be cleared.
If the user continues to hold the “-” button for 1 second
“ClEAr” will disappear and be replaced by .0, indicating
that the selected pair of counters has been cleared.
Clearing Counters
When the desired counter number is displayed, press the
“-” (RESET) button and “ClEAr” will be displayed.
NOTE:
holding the “-” (RESET) button for 1 second will clear both
the #3 AREA counter and the #3 VOLUME counter whether
the rotary switch is in the AREA or the VOLUME position.
If
the “-” button is released before 1 second has elapsed, the
counters will not be cleared and the “ClEAr” message will be
replaced with the previous total.
WIDTH
CAL
FLOW
CAL
MIn
FLOW
ADJUST
rATE
TArGET
rATE
SPEED
CAL
InLInE
BYPASS
TEST
SPEED
VOLUME /
MInUTE
DISTAnCE
ArEA /
HOUr
VOLUME
(1) (2) (3)
rATE
SPEED
ArEA
(1) (2) (3)
On
OFF
1
2
3
4
5
B O O M S
rUn
HOLD
CAL
AUTO
MAn
rESET
On / OFF
____
APPLICATIOn rATE
TAnK
___
HOLD
V
2
WIDTH
CAL
FLOW
CAL
MIn
FLOW
ADJUST
rATE
TArGET
rATE
SPEED
CAL
InLInE
BYPASS
TEST
SPEED
VOLUME /
MInUTE
DISTAnCE
ArEA /
HOUr
VOLUME
(1) (2) (3)
rATE
SPEED
ArEA
(1) (2) (3)
On
OFF
1
2
3
4
5
B O O M S
rUn
HOLD
CAL
AUTO
MAn
rESET
On / OFF
____
APPLICATIOn rATE
TAnK
___
HOLD
V
3
WIDTH
CAL
FLOW
CAL
MIn
FLOW
ADJUST
rATE
TArGET
rATE
SPEED
CAL
InLInE
BYPASS
TEST
SPEED
VOLUME /
MInUTE
DISTAnCE
ArEA /
HOUr
VOLUME
(1) (2) (3)
rATE
SPEED
ArEA
(1) (2) (3)
On
OFF
1
2
3
4
5
B O O M S
rUn
HOLD
CAL
AUTO
MAn
rESET
On / OFF
____
APPLICATIOn rATE
TAnK
___
HOLD
V
1
Display indicates counter pair #2 is selected
Display indicates counter pair #3 is selected
Display indicates counter pair #1 is selected
12
MAn
HOLD
3
WIDTH
CAL
FLOW
CAL
MIn
FLOW
ADJUST
rATE
TArGET
rATE
SPEED
CAL
InLInE
BYPASS
TEST
SPEED
VOLUME /
MInUTE
DISTAnCE
ArEA /
HOUr
VOLUME
(1) (2) (3)
rATE
SPEED
ArEA
(1) (2) (3)
On
OFF
1
2
3
4
5
B O O M S
rUn
HOLD
CAL
AUTO
MAn
rESET
On / OFF
____
APPLICATIOn rATE
TAnK
___
HOLD
V
3
After the “-” (RESET) button has been held for 1 second, the
“ClEAr” message will be replaced by “.0”, indicating that
counter pair #3 has been cleared.