Make sure your system is properly calibrated before beginning 

to  apply  product.    We  also  recommend  completion  of  the 

Pre-Field  System  Checkout  described  on  pages  39-40  prior 

to beginning any field operations.
Press  the  ON/OFF  button  to  turn  the  console  on.    After 

displaying the hours of operation and software version, the 

console will start normal operating mode.
The  MT-3405F™  II  can  be  operated  in  Manual  (MAN)  or 

Automatic  (AuTO)  mode.    In  either  mode,  the  right-hand 

display  will  always  show  the  Application  Rate  (except 

when  in  HOlD  or  when  displaying  error  messages,  see 

Troubleshooting section starting on page 33).  The left hand 

display will show data as selected by the rotary switch.

Manual Operation

The  manual  mode  is  used  when  the  operator  wants  to 

manually control the servo valve using the “+” and “-” keys, 

and thus the application rate.   The application rate (gal/acre 

or liter/hec) will vary depending on ground speed.   use the 

AuTO/MAN button to select MANual mode (“MAN” icon will 

be displayed).

IN HOLd:

 

 If the console is in HOlD, or if all Boom Valves are 

OFF, the “+” and “-” buttons will not control the servo valve 

unless the rotary switch is in the VOluME/MINuTE position.  

In that position only, the servo valve can be adjusted without 

any boom valves on.  This can be useful for system pressure 

tests, etc. 

IN RUN,  wITH  spEEd  sIGNAL: 

  If  the  system  is  in  RuN, 

with at least one boom valve ON and there is a speed signal, 

the “+” and “-” buttons can be used to adjust the servo valve 

with the rotary switch in any position except TANK, VOluME, 

and AREA and the application rate can be monitored on the 

right-hand display.

IN RUN, NO spEEd sIGNAL:

 

 If there is no speed signal, 

“no  SPEEd”  will  flash  in  the  right-hand  display  and  the 

Application Rate will be invalid.  The “+” and “-” buttons will 

adjust the servo valve if the rotary switch is in the VOluME/

MINuTE  position,  and  the  flow  rate  (GPM  or  lPM)  can  be 

monitored.

Turn rotary dial to display desired readout.

WIDTH

CAL

FLOW

CAL

MIn

FLOW

ADJUST

rATE

TArGET

rATE

SPEED

CAL

InLInE

BYPASS

TEST

SPEED

VOLUME /

MInUTE

DISTAnCE

ArEA /

HOUr

VOLUME

(1) (2) (3)

rATE

SPEED

ArEA

(1) (2) (3)

On

OFF

1

2

3

4

5

B O O M S

rUn

HOLD

CAL

AUTO

MAn

rESET

On / OFF

____

APPLICATIOn rATE

TAnK

___

HOLD

V  

  3   

Operation

10

Summary of Contents for MT-3405 F II

Page 1: ...MT 3405F II Dual Display automatic rate controller Operation and Calibration Reference Manual...

Page 2: ...adar or GPS Speed Sensor Calibration 6 Determining the Speed Cal 7 Drive Shaft Speed Sensor Calibration 7 Test Speed 7 Exiting Calibration 7 Factory loaded Calibration Values 7 Special Calibration 8 9...

Page 3: ...m automatic control to manual CAL This key is used to enter exit the calibration mode Key Functions PROGRAM KEYS Used to increment and decrement the different calibration values RESET when not in CAL...

Page 4: ...hold the CAL key until CAL icon appears on the display The con sole is now in cal i bra tion and Metric mode is selected Exit CAL by pressing and holding the CAL key until CAL disappears from the dis...

Page 5: ...um rate for the nozzles The minimum flow rate in gallons per minute li ters per minute based on the nozzles being used for the en tire boom on the sprayer DO NOT enter the actual flow of your spray ap...

Page 6: ...glish units the SPEED CAL number is displayed in inches in metric it is displayed in centimeters SPEED CAL DISTAnCE INLINE BYPASS The display will show InLinE or bYPASS Use the or buttons to toggle to...

Page 7: ...ra tion process exit calibration by pressing and holding the CAL button until the RED warning light turns off one sec ond Basic cal i bra tion is now com plete BEFORE beginning application confirm tha...

Page 8: ...ze volume of Full Tank Off or 1 65 535 Off Tank Low Set Point Sets Alarm Set Point if using TANK Function Off or 1 65 535 Off Auto Shut off Runs Servo Toward Minimum when in Hold On Off Off Auto Delay...

Page 9: ...aution when increasing the valveresponsespeed Ifusing a relatively fast valve 1 3 seconds open to close the system may become unstable with higher valve response speed numbers entered TEST SPEED SPEED...

Page 10: ...he console is in HOLD or if all Boom Valves are OFF the and buttons will not control the servo valve unless the rotary switch is in the VOLUME MINUTE position In that position only the servo valve can...

Page 11: ...AUTO FILL feature is active this feature allows the TANK counter to be quickly reset to a full tank amount by simply pressing the button with the rotary switch in the TANK position The button can be...

Page 12: ...ues to hold the button for 1 second CLEAr will disappear and be replaced by 0 indicating that the selected pair of counters has been cleared Clearing Counters When the desired counter number is displa...

Page 13: ...NOTES 13...

Page 14: ...A N U F A C T U R E D I N U S A BY 111 E LeRay Avenue P O Box 99 Eagle Lake MN 56024 0099 Toll Free 800 328 9613 507 257 3600 Fax 507 257 3001 www micro trak com trakmail micro trak com 2007 Micro Tr...

Reviews: