Micro Innovation MSystem GF0 Manual Download Page 36

Device description GF0

 

MICRO PANEL

Revision History

 

 

 

 
36

 

Technical subject to change

M000235-01.DOC

© by Micro Innovation

 

Micro Innovation AG 

Spinnereistr 8-14 

CH-9008 St. Gallen 

Switzerland

 

 
Tel 

:   ++41- 71 243 24 24 

Fax 

:   ++41- 71 243 24 90 

email : 

 

[email protected] 

homepage :   http://www.microinnovation.com

 

 

 

efesotomasyon.com - Klockner Moeller - inverter

Summary of Contents for MSystem GF0

Page 1: ...scription Micro Innovation AG x Spinnereistrasse 8 14 x CH 9008 St Gallen x Switzerland Tel 41 0 71 243 24 24 x Fax 41 0 71 243 24 90 www microinnovation com x info microinnovation com GF0 efesotomasy...

Page 2: ...tion as well as distribution to third parties can only be made with the express permission of Micro Innovation AG Micro Innovation AG does not accept any liability for damages arising from the use of...

Page 3: ...Innovation AG Warning No warranty claims will be recognized for faults arising from the improper handling of any device Devices and communication should not be used for the implementation of any safe...

Page 4: ...system power supply 15 7 Connection to the communication interface 16 7 1 Preparing the connection cable EMC 16 7 2 Preparing the shield connections 17 8 Connection and function of the programming por...

Page 5: ...ubject to change M000235 01 DOC by Micro Innovation 5 14 Display 27 15 Maintenance and repair 28 16 Disposal 29 17 Technical data 30 18 EC Conformity 32 19 UL Listing 33 20 Revision History 34 efesoto...

Page 6: ...or damage to property may occur if the relevant precautionary measures are not observed The individual Warning pictogrammes have the following meaning Caution General This type of warning must be obse...

Page 7: ...he Micro Panel GF0 Download is implemented via a serial interface The project data is then stored inside the device in a retentive memory The Micro Panel GF0 is provided with a slot for the communicat...

Page 8: ...wing front plate versions are available xx0 Device types with 4 hole aluminium front Section 4 1 xx1 Device types with corrosion resistant stainless steel front 1 4301 Section 4 1 xx2 Device types wit...

Page 9: ...utton Section 9 All mounting versions allow protection in compliance with IP65 Section 5 2 The Micro Panel GF0 can be operated at an ambient temperature of up to 50 C Section 17 The ambient temperatur...

Page 10: ...5 144 The figure above shows the dimensions of the GF0 57xxx xx0 devices These units are provided with a four hole aluminium front The devices with threaded bolts xx1 xx3 have identical outer dimensi...

Page 11: ...ICES Cutout and hole pattern for device versions with 4 hole aluminium front xx0 Front panel cutout 203x147mm centrally to fixing holes Fixing screws M4 countersunk screw Cutout and hole pattern for d...

Page 12: ...AL 7016 The figure above shows the dimensions of the GF0 10xxx xx0 devices These units are provided with a four hole aluminium front The devices with threaded bolts xx1 xx3 have identical outer dimens...

Page 13: ...ES Cutout and hole pattern for device versions with 4 hole aluminium front xx0 Front panel cutout 316x244 mm centrally to fixing holes Fixing screws M5 countersunk screw Cutout and hole pattern for de...

Page 14: ...nk screws must be tightened evenly and securely Observe the general mounting instructions Section 4 1 5 2 MOUNTING ACCORDING TO DEGREE OF PROTECTION IP 65 An additional mounting kit is available for m...

Page 15: ...the connection of the Micro Panel GF0 Carry out the connection as follows The cross section of the supply cable must be between 0 75mm and 2 5mm A lead or wire can be used for the connection The powe...

Page 16: ...rned as to how to connect the shield at the other end If no specifications are given connect the cable shield also at this end to the metal or metallised connector casing Avoid leaving the shield open...

Page 17: ...d braid by approx 3 cm 3 Turn back the braid over the cable sheath 4 Use a heat shrinkable tubing or rubber grommet to cover the exposed cable sheath with the folded back shield braid so that 5 to 8 m...

Page 18: ...O design software for information on the connection and operation of a printer printer installation The programming port is a standard RS232 interface The GND terminal is located directly on the housi...

Page 19: ...is used to load the runtime program This runtime program GRSW contains the function for loading project data and so this program must be loaded before the loading of project data is at all possible Pr...

Page 20: ...es not find an integral runtime program the Micro Panel GF0 switches to the SERIAL DOWNLOAD system mask In this mode the Micro Panel GF0 will try to establish a connection to the PC via the programmin...

Page 21: ...o establish a connection to the PC via the programming port PROG PORT The design software GALILEO can then be used to load project data and or to reload the runtime program System mask for serial data...

Page 22: ...information concerning currently available communications cards and communication protocols Safety precautions concerning electrostatic discharge ESD must be observed when handling cards Never plug i...

Page 23: ...evice 11 2 MEMORY EXPANSION The Micro Panel GF0 is provided as standard with a fixed memory of 4MByte A memory expansion socket is also provided for the device concerned Section 17 Only one memory exp...

Page 24: ...PROGRAMMING PORT PROG PORT Pin 9 of the PROG PORT can also be used for the power supply 5V of external additional hardware jumper J7 on the main board set to position A This is not short circuit proof...

Page 25: ...ransparent plastic frame or the failure of an optical element If this LED is lit clean the plastic frame on the device front Section 13 3 RUN ACTUATE The LED green remains unlit when the system voltag...

Page 26: ...a retentive memory If the signal of one or several channels is below a minimum level relative to the initial values this will be indicated by an error message on the screen and the DEF DIRTY LED Secti...

Page 27: ...l determine the lifespan of the screen Reducing the brightness can significantly increase the lifespan of the LCD display Frequent switching especially at low temperatures will reduce the lifespan The...

Page 28: ...ouch screen operation Section 13 3 Repairs to the Micro Panel GF0 must only be carried out by the manufacturer or Micro Innovation repair centres Contact in this case your local Micro Panel dealer or...

Page 29: ...of properly or returned to the manufacturer for disposal manufacturer address for Micro Panel GF0 see last page Special note The clock module contains a sealed lithium battery Real Time Clock Dallas...

Page 30: ...saver GF0 57SQD 20 000 POH GF0 10xVD 25 000 POH Operation MDS TCL2 Optical light matrix in the infrared range IR Touch Section 13 Resolution physical GF0 57xQD GF0 10xVD 24 x 16 13 x 15 Pixel 40 x 30...

Page 31: ...upply Rated voltage SELV 24 VDC Safety extra low voltage Section 6 Voltage range 24 VDC to DIN 19240 20 4 28 8 VDC effective absolute value with ripple 18 5 30 2 VDC 35 0 VDC for 100ms Voltage dips 5...

Page 32: ...romagnetic compatibility 89 336 EEC and electrical safety Low Voltage Directive 73 23 EEC The generic standards below were used to assess the electromagnetic compatibility of the Micro Panel GF0 EN 50...

Page 33: ...L File E208621 Representative sampels of the Micro Panel GF0 have been evaluated by Underwriters Laboratories Incorporation and meet the applicable United States and Canadian safety standards To asses...

Page 34: ...0 MICRO PANEL Revision History 34 Technical subject to change M000235 01 DOC by Micro Innovation 20 REVISION HISTORY Index Date Visum Alteration 01 12 11 03 RA Included in DokV efesotomasyon com Klock...

Page 35: ...MICRO PANEL Device description GF0 Revision History Technical subject to change M000235 01 DOC by Micro Innovation 35 efesotomasyon com Klockner Moeller inverter...

Page 36: ...ect to change M000235 01 DOC by Micro Innovation Micro Innovation AG Spinnereistr 8 14 CH 9008 St Gallen Switzerland Tel 41 71 243 24 24 Fax 41 71 243 24 90 email info microinnovation com homepage htt...

Reviews: