XPANSION AND CONFIGURATION OPTIONS
11.1 G
ENERAL REQUIREMENTS
The expansion options described in Section 11 require interventions inside the Micro Panel GF0.
These modifications and expansions must only be carried out with the power supply disconnected, i.e.
with the panel in a de-energised state.
Interventions in the device must only be carried out with the power supply
disconnected ! During operation some live parts carry dangerous voltages !
Safety precautions concerning electrostatic discharge (ESD) must be taken when
making interventions in the device.
11.2 M
EMORY
E
XPANSION
The Micro Panel GF0 is provided as standard with a fixed memory of 4MByte. A memory expansion
socket is also provided for the device concerned (
→
Section 17). Only one memory expansion with
the appropriate memory size can be fitted (not cascadable).
To fit the memory expansion remove the communications card from the COM SLOT and unscrew the
device. As shown in the figure below, the memory expansion is fitted directly on the main board and
fastened with screws. The memory expansion is coded by the connector used, thus preventing
incorrect fitting. A change in memory capacity is automatically detected by the system.
The two screws required (M2.5 x 5) are supplied with the memory expansion.