Page 18
Technical Data
thermoIMAGER TIM
Model TIM
400
450
G7
Temperature ranges
(scalable)
20 ... 100 °C; 0 ... 250 °C;
150 ... 900 °C;
Option: 200 … 1500 °C
-20 ... 100 °C; 0 ... 250 °C;
150 ... 900 °C
200 ... 1500 °C
Spectral range
7.5 - 13 μm
7.9 μm
Detector
UFPA,
382 x 288 Pixel@80 Hz (switchable to 27 Hz)
Lenses (FOV)
13 ° x 10 °; 29 ° x 22 °; 38 ° x 29 °
1)
;
53 ° x 40 °;
62 ° x 49 °
1
; 80 ° x 56 °
13 ° x 10 °; 29 ° x 22 °;
53 ° x 40 °; 80 ° x 56 °
System accuracy
2)
±2 °C or ±2 %
Temperature resolution
(NETD)
0.08 K
3)
with 38 ° and 62 °;
0.1 K
3)
with 13 °
0.04 K
3)
with 38 ° and 62 °;
0.1 K
3)
with 13 °
130 mK (T
obj
= 650 °C)
Warm-up time
10 min
Emissivity
0.100 ... 1.100
Software
TIMConnect
1) Not available anymore
2)
At ambient temperature 23±5 °C; whichever is greater.
3)
Value is valid at 40 Hz and 25 °C room temperature.