4. 

Laser Safety

The scanCONTROL 30xx sensors operate with a semiconductor laser with a  
wavelength of 658 nm (visible/red). Operation of the laser is indicated visually by the 
LED on the sensor, see operating instructions Chap. 3.3. When operating the scan-
CONTROL 30xx sensors, the relevant regulations according to IEC 60825, Part 1 of 
05/2014 and the applicable accident prevention regulations must be followed. The laser 
warning labels for Germany have already been attached. For other non German speak-
ing countries, an IEC standard label is included in delivery and the versions valid for the 
user’s country must be attached before the device is put into operation for the first time.

  If both warning labels are covered over when the unit is installed, the user must 

ensure that supplementary labels are applied.

Laser radiation. Close your eyes or immediately turn away if the 
laser beam hits the eye. Irritation or injury of the eyes possible.

Laser Class 2M

The sensors fall within laser class 2M (IIM). The laser is operated on a pulsed mode, the 

maximum optical power is ≤ 10 mW or ≤ 12 mW. Attach the following warning labels to 

the cover (front and rear side) of the sensor housing.

LASER RADIATION

DO NOT STARE INTO BEAM

OR EXPOSE USERS OF 

TELESCOPE OPTICS

CLASS 2M LASER PRODUCT

IEC 60825-1: 2014

P

10 mW, P

 10 mW; E  6 mW/cm²;

0

P

λ

 = 658nm; F = 0...25kHz, t = 7µs...∞

LASER RADIATION

DO NOT STARE INTO BEAM

OR EXPOSE USERS OF 

TELESCOPE OPTICS

CLASS 2M LASER PRODUCT

IEC 60825-1: 2014

P

12 mW, P

 12 mW; E  6 mW/cm²;

0

P

λ

 = 658nm; F = 0...25kHz, t = 7µs...∞

Fig. 1 LLT30xx-25, LLT30xx-50, LLT30xx-100

Fig. 2 LLT30xx-200

COMPLIES WITH 21 CFR 1040.10 AND 1040.11 

EXCEPT FOR CONFORMANCE WITH 

IEC 60825-1 ED. 3., AS DESCRIBED IN

LASER NOTICE NO. 56, DATED MAY 8, 2019

Only for USA

i

 Mark the laser area recognizable 

and everlasting.

Laser Class 3R

The sensors with the /3R option fall within laser class 3R. The laser is operated on a 

pulsed mode, the maximum optical power is ≤ 30 mW or ≤ 50 mW. Attach the follow

-

ing warning labels to the cover (front and rear side) of the sensor housing.

LASER RADIATION

AVOID DIRECT EYE EXPOSURE

CLASS 3R LASER PRODUCT

IEC 60825-1: 2014

P

 ≤

30mW, P

 ≤

 30mW; E

 ≤

 18mW/cm²;

0

P

λ

 = 658nm; F = 0...25kHz, t = 7µs...

Fig. 3 LLT30xx-25, LLT30xx-50

Fig. 4 LLT30xx-100, LLT30xx-200

COMPLIES WITH 21 CFR 1040.10 AND 1040.11 

EXCEPT FOR CONFORMANCE WITH 

IEC 60825-1 ED. 3., AS DESCRIBED IN

LASER NOTICE NO. 56, DATED MAY 8, 2019

Only for USA In addition, the following information label 

must be attached to the laser output on 
the sensor housing: 

i

  Class 3R laser sensors require a 

laser protection officer.

LASER

APERTURE

 

Summary of Contents for scanCONTROL 30 BL Series

Page 1: ...etergents cooling emulsions Damage to or destruction of the sensor Read the detailed operating instructions before operating the sensor These instructions are available online at www micro epsilon com...

Page 2: ...he sensor housing LASER RADIATION DO NOT STARE INTO BEAM OR EXPOSE USERS OF TELESCOPE OPTICS CLASS 2M LASER PRODUCT IEC 60825 1 2014 P 10 mW P 10 mW E 6 mW cm 0 P 658nm F 0 25kHz t 7 s LASER RADIATION...

Page 3: ...ns LED Displays 1 2 1 Multifunction port power supply I O 2 Ethernet port Multifunction Port Designation Sensor connector pin Cable color PCR3000 x Notes Ub 9 Red 11 V 30 V DC rated value 24 V max 5 W...

Page 4: ...ts of the multifunction port can either be used for encoder input trigger input or for load previously stored user modes The signal levels are switchable for all switching inputs between LLL TTL logic...

Page 5: ...is setting is activated by default and has priority over search the link local net The sensor scanCONTROL 30xx supports Power over Ethernet If the sensor is connected to a POE capable network adapter...

Page 6: ...us RTU protocol Measurement value transmission in ASCII format 7 System Requirements scanCONTROL Configuration Tools The following minimum system requirements are necessary Windows 7 Windows 8 or 8 1...

Page 7: ...Close unused connection plugs with the included protective caps Turn on the power supply 24 VDC Please wait until the scanCONTROL measuring system is recognized by the PC This may take a few seconds N...

Page 8: ...scanCONTROL and the PC On the left side you can adjust the settings for your measurement task the right side shows the profile data and information about the measurement 10 How to Access Profile Data...

Page 9: ...us systems Furthermore all scanCONTROL sensor settings can be set via the 2D 3D Gateway e g Laser on off or switch User Mode Sensor parameterization Power supply Triggering Encoder Synchronization Mod...

Page 10: ...ply OUT 24 V 0 V 0 V System supply In 24 V 0 V OU filter module 2 5 3 0 5 7 LINK ACT MS I O ETHERNET NS 8 7 6 5 4 3 2 1 N O LINK ACT 1 2 X 1 X 2 8 1 ON 24V X3 0V 0 WBM 255 DHCP OU fieldbus coupler L1...

Page 11: ...e Digital output terminals need a field supply of 5 VDC or 24 VDC depending on the module type After mounting the modules install the required wiring Connect the System supply out contacts of the OU F...

Page 12: ...ocumentation the Status and Error Messages and Notes sections in the scanCONTROL Configuration Tools operating instructions You will find details about the individual programs in the respective operat...

Reviews: