scanCONTROL 3010 / 3012

2

3

4

5

6

7

8

9

1

10

11

12

GND: galvanically isolated from In1, In2, In3, In4, 
RS422, laser on/off 

Laser on/off: input galvanically isolated from GND, 
In1, In2, In3, In4, RS422

In1, In2, In3, In4, RS422: inputs galvanically isolat-
ed from GND and laser on/off

12-pin screw connector, view on solder side (cable)

RS422, Synchronization

The RS422 connection (pins 11 and 12 of the multifunction port) can be used in either 
of the following configurations:

 - RS422 (half-duplex): Load user modes, sensor control and transmit measurement 

results (Modbus RTU or ASCII format).

 - Synchronization/triggering: Synchronization or triggering using switching signals.

Trigger, Encoder, Mode Switching

The switching inputs of the multifunction port can either be used for encoder input, 
trigger input or for load previously stored user modes. 
The signal levels are switchable for all switching inputs between LLL (TTL logic) and 
HLL (HTL logic):

 - LLL level: Low 0 V … 0.8 V, high  2.4 V … 5 V, internal pull-up/down switchable resis-

tor 10 kΩ

 - HLL level: Low 0 V … 3 V, high 11 V … 24 V (permitted to 30 V), internal pull-up/

down switchable resistor 10 kΩ

 -

Pulse duration: ≥ 5 µs

External Laser Switch-off, Optional

Externally switching off the laser is implemented as a hardware solution and is a top 
priority. The laser can also be switched off by software.

This function is offered by sensors with the /SI option.

  Use a serial key switch in the control circuit to switch off the laser. 

With standard sensors, connecting the supply voltage activates the laser light source in 
the sensor.

Wiring details are available in the operating instructions, Chap. 5.2.6.

Summary of Contents for scanCONTROL 30 BL Series

Page 1: ...etergents cooling emulsions Damage to or destruction of the sensor Read the detailed operating instructions before operating the sensor These instructions are available online at www micro epsilon com...

Page 2: ...he sensor housing LASER RADIATION DO NOT STARE INTO BEAM OR EXPOSE USERS OF TELESCOPE OPTICS CLASS 2M LASER PRODUCT IEC 60825 1 2014 P 10 mW P 10 mW E 6 mW cm 0 P 658nm F 0 25kHz t 7 s LASER RADIATION...

Page 3: ...ns LED Displays 1 2 1 Multifunction port power supply I O 2 Ethernet port Multifunction Port Designation Sensor connector pin Cable color PCR3000 x Notes Ub 9 Red 11 V 30 V DC rated value 24 V max 5 W...

Page 4: ...ts of the multifunction port can either be used for encoder input trigger input or for load previously stored user modes The signal levels are switchable for all switching inputs between LLL TTL logic...

Page 5: ...is setting is activated by default and has priority over search the link local net The sensor scanCONTROL 30xx supports Power over Ethernet If the sensor is connected to a POE capable network adapter...

Page 6: ...us RTU protocol Measurement value transmission in ASCII format 7 System Requirements scanCONTROL Configuration Tools The following minimum system requirements are necessary Windows 7 Windows 8 or 8 1...

Page 7: ...Close unused connection plugs with the included protective caps Turn on the power supply 24 VDC Please wait until the scanCONTROL measuring system is recognized by the PC This may take a few seconds N...

Page 8: ...scanCONTROL and the PC On the left side you can adjust the settings for your measurement task the right side shows the profile data and information about the measurement 10 How to Access Profile Data...

Page 9: ...us systems Furthermore all scanCONTROL sensor settings can be set via the 2D 3D Gateway e g Laser on off or switch User Mode Sensor parameterization Power supply Triggering Encoder Synchronization Mod...

Page 10: ...ply OUT 24 V 0 V 0 V System supply In 24 V 0 V OU filter module 2 5 3 0 5 7 LINK ACT MS I O ETHERNET NS 8 7 6 5 4 3 2 1 N O LINK ACT 1 2 X 1 X 2 8 1 ON 24V X3 0V 0 WBM 255 DHCP OU fieldbus coupler L1...

Page 11: ...e Digital output terminals need a field supply of 5 VDC or 24 VDC depending on the module type After mounting the modules install the required wiring Connect the System supply out contacts of the OU F...

Page 12: ...ocumentation the Status and Error Messages and Notes sections in the scanCONTROL Configuration Tools operating instructions You will find details about the individual programs in the respective operat...

Reviews: