background image

 
 
Assembly Instructions 

opto

CONTROL 

2520  

 

Functions 

 

Edge measurement with the shadow principle (Edge low-high; edge high-low) 

 

Measurement of diameter-, width-, gap incl. center axis 

 

Counting of edges or segments, any segment situations or widths; calculation of the center 
axes between edges 

 

Trigger, synchronization and further functions 

 

RS422, Ethernet or EtherCAT interface, transfer of sveral measuring values to the PC 

 

Measuring rate 2.5 kHz 

 

Warnings 

Connect the power supply according to the safety regulations for electrical operating equipment. 
Supply voltage must not exceed specified limits.  
> Danger of injury, damage to or destruction of the sensor 
Protect cables against damage. 
> Failure of the measuring device 
Avoid shock and vibration to the light source and the receiver. 
> Danger of injury, damage to or destruction of the sensor 

 

Notes on CE Identification 

The following applies to the optoCONTROL 2520: EMC 

regulation 2004/108/EC 
The sensor satisfies the requirements according to the 
standards 

EN 61000-6-3 / EN 61326-1 (class B) emitted interference 
EN 61000-6-2 / EN 61326-1 interference immunity 

 

Proper Environment 

Protection class:  

IP 64 applies only with connected cable (with protective cap on Ethernet 

connector) 

Operating temperature: +5 ... +50 °C  
Storage temperature:  -20 ... +70 °C 

 
 

 
 
 
 
 

 
 
 
 
 

 
 
 
 

 
 
 
 
 

optoCONTROL 2520 

 

 

1

 

Summary of Contents for optoCONTROL 2520

Page 1: ...Assembly Instructions optoCONTROL 2520...

Page 2: ...W rner Stra e 101 73037 G ppingen Germany Tel 49 7161 98872 300 Fax 49 7161 98872 303 e mail eltrotec micro epsilon de www micro epsilon com Zertifiziert nach DIN EN ISO 9001 2008 Certified acc to DI...

Page 3: ...ply voltage must not exceed specified limits Danger of injury damage to or destruction of the sensor Protect cables against damage Failure of the measuring device Avoid shock and vibration to the ligh...

Page 4: ...the connectors and the display elements Connect the components Dimensional Drawings Light source and receiver Dimensional Drawings Light Source and Receiver with Mounting Rail Light Source Female Conn...

Page 5: ...rically isolated only one measuring value 14 bit D A Shielded inner cable White inner conductor Ana GND Ground analog output Reference ground for analog signal Shielded inner cable Shielding braid PE...

Page 6: ...exe Start the SensorFinder and press the Find sensors button Select the correct sensor from the list Press the Start browser button in order to connect the sensor with your standard browser The start...

Page 7: ...tly parallel to the laser beam Controlling the Video Signal Open the menu Video signal and check it The edges to be measured have to cross the detection threshold Should a transparent measuring target...

Page 8: ...RO EPSILON Eltrotec GmbH Manfred W rner Stra e 101 73037 G ppingen Germany Tel 49 0 7161 98872 300 Fax 49 0 7161 98872 303 eltrotec micro epsilon de www micro epsilon com X9771306 A011059HDR X9751306...

Reviews: