Power Signals Female Connector (14-pin)
A cable with open ends (PC/SC2520-3) is included.
Signal Description
Comments
Cable
color
24 VDC
Operating voltage
11 … 30 VDC, I max < 1 A
Red
GND
Operating voltage
ground
Black
Out 1
Switching output 1
Blue
Out 2
Switching output 2
Error or limits, not electrically isolated,
24 V logic (HTL), High level depends on
operating voltage
Pink
In
Input
Zeroing/mastering
Or reset to factory
settings
Not electrically isolated, 24 V logic
(HTL),
Low level
≤
3 V,
High level
≥
10 V
Gray/pink
Sync - In/out
White/green
/Sync - In/out
Input synchronization
or triggering,
synchronous output
symmetrical, RS422 level, load
resistance 120 Ohm and direction via
software switchable,
not electrically isolated
Red/blue
RX - 422
Brown
/RX - 422
Serial input, symmetrical, internally
terminated with 100 Ohm
Green
/TX - 422
Yellow
TX - 422
RS422
Serial output RS422, symmetrical
Grey
GND - RS 422
Ground
Groud reference for RS422-Pegel
Violet
Ana - Out
Voltage output
0 ... 10 V, not electrically isolated, only
one measuring value, 14 bit D/A
Shielded inner
cable:
White inner
conductor
Ana - GND
Ground analog
output
Reference ground for analog signal
Shielded inner
cable:
Shielding braid
PE
Total outer shield
Connect with PE of the system
Black shrinking
hose with wire end
Connect at least the power supply and switch it on.
Adjust the position of the light source in direction to the receiver when mounting without rail.
The laser light has to hit exactly the center of the entry window of the receiver.
Please consider: The larger the distance between light source and receiver, the more exactly has to
be adjusted.
Ethernet/EtherCAT Female Connection (4-pin)
Electrically isolated M12x1-female connection in combination with an Ethernet-network (PC) or with
the bus system EtherCAT. There is an Ethernet cable with straight plug on RJ45-plug, 3 m long
(accessory). The receiver is connected with a PC or generally with a network via the Ethernet
interface. The internal web pages can be retrieved with a web browser and thereby the measuring
system can be configured.
Signal
Pin female
connector
RX+ 2
RX- 4
TX+ 1
TX- 3
Solder pin side on
the cable
optoCONTROL 2520