Page 30
Operation
MSC7401 Miniature sensor controller for inductive sensors
5.4.2
Zero Point Search
D1:
Channel
D2:
E1
D3:
E2
D4:
Value
G
G
O
LED off
Set the output signal U
0
.
Preset is 6 VDC or 12 mA.
ENTER
G
O
LED flashes and color
changes depending
on the output signal
(green = too low red
= too high).
O
Move the measuring object to the position X
0
until the
output reaches U
0
.
Lights orange, when
the measuring object
is in the electrical
center of the sensor.
ENTER
G
O
LED color changes
depending on the
target position.
O
Move the measuring object to the position X
2
1
and
change the output signal U
2
with
Flashes orange,
when the measuring
object is in the elec-
trical center of the
sensor.
Fig. 22 Menu structure controller MSC 7401, adjustment mode: Zero point search
1) Position X
2
must
be > 10 % of the
measuring
range from X
1
.