background image

Page 8

Functional Principle, Technical Data

Industrial Performance Unit

2.3 

Special Performance Features

The Industrial Performance Unit is characterized by its compact design while at the same time achieving high throughput 
of 3D points.

 

-

High-performance solution for 3D measuring tasks

 

-

Full compatibility and inline capability for customer applications

 

-

Intuitive 3DInspect software with Valid3D technology by Micro-Epsilon

 

-

Efficient commissioning of Micro-Epsilon sensors

 

-

Integrated interfaces: PROFINET, EtherNet/IP

 

-

Industrially compatible hardware with passive cooling

2.4 

Technical Data

Model

Industrial Performance Unit

RAM

16 GB

Memory

128 GB SSD

Supply voltage

9 ... 36 V DC

Power consumption

50 W (max. 112 W)

Digital interfaces

Gigabit Ethernet (GigE Vision / GenICam) / PROFINET / EtherNet/IP

Connection

4-pin supply terminal block; 2x RJ45 for Gigabit Ethernet, 

2x RJ45 for Industrial Ethernet (PROFINET or EtherNet/IP); 

1x HDMI, 1x VGA, 1x USB3.2 (Gen1); 4x USB2.0

Mounting

Mounting holes, 

Accessories for table or wall mounting and DIN rail mounting

Temperature range

Storage

-40 ... +85 °C

Operation

 1

0 ... +50 °C

Shock (DIN EN 60068-2-27)

20g / 11 ms half-sine

Vibration (DIN EN 60068-2-6)

3 g / 5 ... 500 Hz

Protection class 

IP40

Material

Metal housing

Weight

2.8 kg

Control and indicator elements

2 LEDs for storage and power; 4 LEDs for status display of Ethernet 

1 power on/off switch

Special features

Windows 10 IoT Enterprise

   
 1) Maximum permissible operating temperature at 0.7 m/s air flow

Summary of Contents for Industrial Performance Unit

Page 1: ...Operating Instructions Industrial Performance Unit...

Page 2: ...MICRO EPSILON MESSTECHNIK GmbH Co KG K nigbacher Str 15 94496 Ortenburg Deutschland Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 e mail info micro epsilon com www micro epsilon com...

Page 3: ...ge 10 4 Installation and Assembly 11 4 1 Controller 11 4 2 Electrical Connections 12 4 2 1 Connection Diagram 12 4 2 2 Interfaces 13 4 2 3 Supply Voltage Power 13 4 3 Installation instructions 14 4 4...

Page 4: ...Industrial Performance Unit...

Page 5: ...ge to or destruction of the controller The supply voltage must not exceed the specified limits Damage to or destruction of the controller Lay the power supply cable according to the provisions for ele...

Page 6: ...easuring system is designed for use in industrial environments The EU Declaration of Conformity and the technical documentation are available to the responsible authorities according to the EU Directi...

Page 7: ...re Industrial Ethernet TCP IP UDP Modbus protocol or the fieldbuses listed below are available for outputting results and controlling the system PROFINET EtherNet IP The flexible industrial grade hard...

Page 8: ...GB Memory 128 GB SSD Supply voltage 9 36 V DC Power consumption 50 W max 112 W Digital interfaces Gigabit Ethernet GigE Vision GenICam PROFINET EtherNet IP Connection 4 pin supply terminal block 2x R...

Page 9: ...eaning Off No access to hard drive On Read write access to hard drive LAN 1 2 LEDs Meaning Link LED left Constant orange Gigabit Ethernet connection established Constant green 100 Mbit Ethernet connec...

Page 10: ...oller 2 mounting adapters for table wall mounting Carefully remove the components of the measuring system from the packaging and ensure that the goods are for warded in such a way that no damage can o...

Page 11: ...destruction of the controller possible 77 3 03 82 2 3 24 192 7 56 224 8 82 250 9 84 22 87 186 7 32 230 9 01 40 1 57 150 5 91 5 20 14 55 10 39 Dimensions in mm inches Fig 3 Dimensional drawing of SC25...

Page 12: ...4V scanCONTROL Fig 5 Connecting the scanCONTROL Monitor HDMI cable Controller 3DInspect installed Power supply 24V LAN cable SCR3000X x surfaceCONTROL 3D 35xx surfaceCONTROL 3D 32xx Fig 6 Connecting t...

Page 13: ...ection for monitor 5 Power supply 4 2 3 Supply Voltage Power The power supply connection is a 4 pin plug connector Pin Designation Comments 9 V 36 V DC nominal value 24 V max power consumption 112 W 0...

Page 14: ...duct The minimum bending radii are three times the cable diameter and must not be less than this 4 4 Initial Operation The controller may only be connected to peripherals when it does not carry power...

Page 15: ...ner and may only use this method of access for the aforementioned purposes Any use that extends beyond this in particular any use that endan gers operational safety is prohibited Micro Epsilon is not...

Page 16: ...asuring system straight away After the supply voltage has been applied The controller starts up The operating system is loaded The user Operator is logged in without having to enter a password 3DInspe...

Page 17: ...Data view Using this view align the sensor with the target as best as possible Optimize the sensor parameters so that you get an ideal point cloud Set the evaluation parameters according to the measu...

Page 18: ...s on this in the Running Firmware on the Fieldbus Card section see Chap 7 2 If no error message appears or if a different 3DInspect error message appears after confirming with OK the correct firm ware...

Page 19: ...ick the OK button The path to the firmware is displayed in the Assigned Module Firmware Files section Click the OK or Apply button A dialog with a prompt to restart the fieldbus card will appear Confi...

Page 20: ...g parts and in the event of non compliance with the specified maintenance intervals if applicable MICRO EPSILON is exclusively responsible for repairs It is not permitted to make unauthorized structur...

Page 21: ...ial waste e g residual waste can or the yellow recycling bin and must be disposed of separately This avoids hazards to the environment due to incorrect disposal and ensures prop er recycling of the ol...

Page 22: ...or the MIC 770 contains details about the CPU You can find the user manual on the D drive of the IPU You can find the operating instructions for the 3DInspect software among the documentation for the...

Page 23: ...Page 23 Appendix Accessories Industrial Performance Unit 0 205 5 190 8 10 4 4 9 150 5 5 151 5 Fig 11 Dimensions mounting plate for DIN rail mounting...

Page 24: ...K nigbacher Str 15 94496 Ortenburg Deutschland Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 info micro epsilon com www micro epsilon com Your local contact www micro epsilon com contact worldwide X9751438...

Reviews: