background image

Page 29

 

induSENSOR, EDS

4.4.2 

Model EDS- ... -F

Power supply and signal output are effected through the 5-contact connector on the sensor’s electronic 
housing. The pin assignment is shown, see 

Fig. 22

.

Pin

Assignment

A 5-pin cable socket for the user-side as-
sembly of your own connecting cable is 
part of the delivery scope.

A

Power  (18 ... 30 VDC)

B

Ground

C

4 ... 20 mA

D

Housing

Fig. 22 Table connection pin assignment, 
bayonet connection, view of solder pin 
side female cable connector

E

---

+

_

+

_

18...30 VDC

I

R

U

B

A

L

OUT

B

C

A

D

E

EDS-...-F

R

L

 can be inserted as an option for adap-

tation of the power loss to high ambient 
temperatures, see Chap. 

4.4.4

.

Fig. 23 Signal monitoring with ampere-
meter

Connector 

Type CA02COM-G14S 
 
The C705-5 sensor 
cable is available as an 
accessory.

Summary of Contents for induSENSOR EDS Series

Page 1: ...EDS 75 S EDS 100 S F EDS 160 S F EDS 200 S F EDS 220 Z EDS 250 S F EDS 260 Z EDS 300 S F Z EDS 370 Z EDS 400 S F Z EDS 500 S EDS 630 S F Instruction Manual induSENSOR EDS...

Page 2: ...Long Stroke sensors Series EDS...

Page 3: ...e 9 2 3 Technical Data 10 3 Delivery 12 3 1 Unpacking 12 3 2 Storage 12 4 Installation and Assembly 13 4 1 Precautionary Measures 13 4 2 Measuring Tube Guide and Fastening 13 4 3 Sensor Mounting 15 4...

Page 4: ...induSENSOR EDS 5 Operation 33 6 Operation and Maintenance 33 7 Warranty 34 8 Decommissioning Disposal 34 9 Appendix 35...

Page 5: ...icates a user tip 1 2 Warnings Connect the power supply according to the safety regulations for electrical operating equipment Danger of injury Damage to or destruction of the sensor The supply voltag...

Page 6: ...EPSILON MESSTECHNIK GmbH Co KG K nigbacher Stra e 15 94496 Ortenburg Germany The measuring system is designed for use in industry and satisfies the requirements 1 4 Proper Use The sensors are used for...

Page 7: ...ronics IP 67 1 Operating temperature 40 C up to 85 C 40 up to 185 F RL 500 Ohm Storage temperature 40 C up to 100 C 40 up to 212 F Humidity 5 95 non condensing Ambient pressure 450 105 Pa 1 Pa 1 N m2...

Page 8: ...transferred from the coil by inducing of eddy currents in the aluminium tube and it is detuned as a result The integrated miniaturized electronics convert the tube position into a linear electrical o...

Page 9: ...ressure proof stainless steel housing is available as an option The sen sors are used for measuring lengths from 100 to 630 mm Electrical connection Connector 4 pins type Amphenol C164P compact Model...

Page 10: ...y 0 05 FSO Temperature range 40 C 85 C Temperature stability 200 ppm C Frequency response 3 dB 150 Hz optional up to 300 Hz Output signal 4 20 mA Output load 500 Ohm Power supply 18 30 VDC Current con...

Page 11: ...ensor material V4A Steel 1 4571 Tube material AlMgSi enodized Sensor weight EDS S g 150 170 160 220 250 280 470 560 650 EDS F 1260 1270 1300 1320 1350 1560 1750 EDS Z 340 370 370 570 570 Alu tube S 20...

Page 12: ...stroke displacement sensor includes 1 Eddy current long stroke displacement sensor 1 O ring mounted on sensor 1 1 Measuring tube 1 Test report 1 Instruction manual In case of damage or missing parts...

Page 13: ...and Fastening Mount the measuring tube in the piston bore hold The dimensions for the measuring tube are shown see Fig 8 et seq When the piston is moved in the measu ring tube must not touch the sens...

Page 14: ...point of the measuring tube EDS F a Measuring range Dimension a 75 15 0 59 100 20 0 79 160 20 0 79 200 20 0 79 220 20 0 79 250 20 0 79 260 20 0 79 Fig 4 Zero point of the measuring tube EDS Z 300 20...

Page 15: ...ealing is effected at the sensor shaft by means of an O ring supplied Displacement sensor O ring Piston Sensor shaft Cylinder Sensor rod 21HB Mounting ring M5x10 Alu tube Fig 5 Sensor mounting in a hy...

Page 16: ...6 The bushing must be congruent with the connector for models with radial connector Fig 6 Mounting of an induSENSOR model EDS S Groove Use an extractor for dismounting see Fig 7 Dimensions of the fla...

Page 17: ...ring range 75 2 95 100 3 94 160 6 29 200 7 87 250 9 84 300 11 81 Dimension Fit tolerance m A B 21f7 20 41 EDS xxx S Sx l 1 31 1 2 16 63 EDS xxx S Sx7 l 51 2 0 47 1 85 Dimensions in mm inches not to sc...

Page 18: ...induSENSOR with radial connector model EDS SR7 I measuring range 75 2 95 100 3 94 160 6 29 200 7 87 250 9 84 300 11 81 A EDS xxx S Sx I 1 31 1 2 EDS xxx S Sx7 I 51 2 0 Dimensions in mm not to scale 1...

Page 19: ...l connector model EDS SA7 I measuring range 400 15 74 500 19 69 630 24 80 dimensions in mm inches not to scale Dimension Tolerance m A B 21f7 20 41 EDS xxx S Sx l 1 31 2 19 16 63 EDS xxx S Sx7 l 51 2...

Page 20: ...A Fig 11 induSENSOR with radial connector model EDS SR7 I measuring range 400 15 74 500 19 69 630 24 80 A EDS xxx S Sx I 1 31 1 2 EDS xxx S Sx7 I 51 2 0 Dimensions in mm inches not to scale 1 Previou...

Page 21: ...SOR EDS 80 0 3 15 12 0 47 55 0 2 17 30 0 1 0 04 3 95 0 05 16 0 002 8 0 32 a b c d a 6 2 24 b 34 0 0 05 1 34 0 002 c 31 0 0 1 1 22 0 004 d 16 0 63 Fig 12 Mounting ring model EDS S dimensions in mm inch...

Page 22: ...e sensor shaft by means of an O ring supplied Sensor rod Cylinder Piston Sensor shaft Alu tube O ring Displacement sensor 42F7 Cylinder head bolt M8 Fig 13 Sensor mounting in a hydraulic cylinder mode...

Page 23: ...nsor rod Alu tube L D I d 100 3 93 140 5 51 10 0 39 140 5 51 16 0 63 160 6 29 200 7 87 10 0 39 200 7 78 16 0 63 200 7 87 240 9 45 10 0 39 240 9 45 16 0 63 250 9 84 290 11 42 10 0 39 290 11 42 16 0 63...

Page 24: ...t outwards and connect them with the mounting plug Grub screw Sensor rod Alu tube Piston Back panel O ring Adapter M12x1 Mounting plug 4 pin 48H8 25 18 15 Fig 15 Sensor mounting in a hydraulic cylinde...

Page 25: ...D Fig 16 induSENSOR with axial wires model EDS Z dimensions in mm inches not to scale Measuring range Sensor rod Alu tube L D I d 220 8 66 252 9 92 10 39 250 9 84 16 63 260 10 23 292 11 50 10 39 290...

Page 26: ...17 Female thread in the extractor pipe M24 x 1 5 Proceeding 1 Unplug the adapter 2 Release the grub screw 3 Screw on the extractor pipe on the sensor shaft and pull out the sensor from the cylinder E...

Page 27: ...ted with pin 4 on the electronics board The screen of the sensor cable is connected with the connector hous ing Connect the screen of the sensor cable with the protective earth conductor on power side...

Page 28: ...to high ambient temperatures see Chap 4 4 4 Fig 20 Signal monitoring with amperemeter 2 3 4 1 B V 18 30 VDC _ UOUT U _ RL IS EDS S If the signal is monitored with a voltmeter the load resistor RL is...

Page 29: ...cable is part of the delivery scope A Power supply 18 30 VDC B Ground C 4 20 mA D Housing Fig 22 Table connection pin assignment bayonet connection view of solder pin side female cable connector E _...

Page 30: ...voltmeter 4 4 3 Model EDS Z Power supply and signal output are effected through the 4 contact connector on the hydraulic cylinder The pin assignment is shown see Fig 25 Pin Assignment Color A 4 pin c...

Page 31: ...gh ambient temperatures see Chap 4 4 4 Fig 26 Signal monitoring with amperemeter EDS Z If the signal is monitored with a voltmeter the load resistor RL is dimensioned in ac cordance with the desired o...

Page 32: ...RL is limited by the operating voltage UB U 10 V 20 mA B R L max A small load resistor loads the sensor electronics more thermical With a maximum operating temperature of 85 C 185 F the minimum load r...

Page 33: ...nd of measuring range i The sensor is ready for measuring without adjustment Warm up time 10 min Output signal 4 20 mA 6 Operation and Maintenance Observe the notes on measuring tube guiding during op...

Page 34: ...allation of the devices or from repair or modifications performed by third parties No other claims except as warranted are accepted The terms of the purchasing contract apply in full MICRO EPSILON wil...

Page 35: ...gital output RS232 2 programmable limit switch Tara function C704 90 5 Supply and output cable 90 connector 4 pole 5 m long Model EDS S C704 5 Supply and output cable straight connector 4 pole 5 m lon...

Page 36: ...X9751051 B081115GBR MICRO EPSILON MESSTECHNIK...

Reviews: