background image

 

 

 

 

 

 

 
 

 

 

 

 
 
 
 
 

User manual for 

 

the ILD1700 Tool  

 

Version 1.4 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Summary of Contents for ILD1700

Page 1: ...User manual for the ILD1700 Tool Version 1 4...

Page 2: ...Menu bar 6 3 4 1 FILE 6 3 4 2 PROGRAM 6 3 4 3 LANGUAGE 6 3 4 4 6 4 SENSOR CONFIGURATION 7 4 1 Configuration 7 4 1 1 CONNECTION SETTING 7 4 1 2 SENSOR PARAMETERS 8 4 1 3 CALIBRATION 8 4 1 4 ADDITIONAL...

Page 3: ...__________________ Micro Epsilon Page 3 5 3 Data Storage 14 5 3 1 DATA EXPORT PROPERTIES 14 5 4 Distance View 14 5 4 1 DISTANCE 14 5 4 2 STATISTICS 14 5 4 3 LIMIT OUTPUT PROPERTIES 14 5 4 4 FREEZE MOD...

Page 4: ...lution of 1024x768 Sensor controller firmware version 1 7 or higher IEEE422 RS422 to RS232 converter USB to Serial Port driver version 1 00 2154 FTSER2K SYS or higher 2 2 Software installation Start t...

Page 5: ...priate regional settings only Fig 2 Main Menu 3 1 Show Sensor Manual If you have a PDF viewer installed on your computer the documentation of the ILD1700 Sensor Controller is shown Since the documenta...

Page 6: ...4 2 2 Data Acquisition Switches to the data acquisition and storage program 3 4 2 3 Main Menu Shows the main page again 3 4 3 Language Determines the language of the descriptions and the fonts of the...

Page 7: ...D1700 Sensor Configuration 4 1 1 Connection Setting The COM port the ILD1700 controller is connected to Supported port numbers are COM1 to COM16 The sensor uses a RS422 to USB interface that is mapped...

Page 8: ...see Sensor Information The sensor manual contains a table that shows more on that 4 1 2 3 Output Type The mode RS422 activates the digital data output The items 4 20mA and 0 10V activate the analog da...

Page 9: ...binary mode when started The ASCII mode may be more suitable when using the HyperTerminal or other diagnostic tools to communicate with the sensor 4 1 4 3 Laser Turns the laser diode on or off 4 1 4 4...

Page 10: ...on the parameter Limit Assignment 4 1 6 Sensor Information Displays some general information about the sensor 4 1 6 1 Sensor Range Measurement range of the sensor 4 1 6 2 Read Sensor Info This button...

Page 11: ...___ Micro Epsilon Page 11 4 1 9 Sensor Fallback Reset To Factory Settings Overwrites the parameters stored in the sensor with the default parameters For example sets the baud rate to 115200 Reboot Sen...

Page 12: ...200 8 n 1 5 1 1 1 COM Number of the COM port the ILD1700 sensor is connected to see 4 1 1 5 1 1 2 Block size Determines the number of values to read at once A smaller block size reduces the reaction t...

Page 13: ...ment values in the visible x range Then it sets the upper limit of the y axis to average Y_range and the lower limit to average Y_range 5 1 2 3 Range mm This parameter determines the area of interest...

Page 14: ...ues are displayed in the plot graph because only the displayed values are stored when using the button Store displayed samples 5 4 Distance View This view displays the currently acquired or buffered m...

Page 15: ...ower hysteresis If the measurement value rises above this threshold the lower LED is set to green This threshold is displayed in orange 5 4 3 6 Lower limit If the measurement value falls below this li...

Page 16: ...uffers and switch into live mode 5 4 5 F1 F2 Upper limit This LED displays the state of the output for the upper limit A red LED indicates the upper limit is violated and the corresponding limit outpu...

Page 17: ...ILD1700 Tool ___________________________________________________________________________ Micro Epsilon Page 17...

Reviews: