Page 29
Ethernet Interface
IF1032/ETH
6.2.1
Settings for Analog Inputs
Operating Modes:
- Continuous transmission with fixed data rate
- Trigger mode (hardware trigger input), see Chap.
5.4
.
Data rate:
It is possible to adjust different data rates between 2.0 Sa/s and 4 kSa/s. The data rate applies to all channels.
6.2.2
Settings for Sensors via RS485
Depending on the sensor.
6.3
Commands
All commands are transmitted via port 23 (Telnet). Each command starts with a $ character. The interface
module ignores all characters, which are transmitted before the $ character.
The interface module immediately returns all transmitted characters back as echo.
Commands are transmitted in ASCII format.
A time out is reached approximately 10 seconds after the last character input.
Channel numbers are separated by a comma, channel number and a parameter belonging to the channel by
a colon.
Several successive different parameters (for the command STS and VER) are separated by a semicolon.
Commands always have to end with <CR> or <CRLF>.