Page 103
Appendix | Factory Settings
thermoMETER CT
Model
CT-SF02/15/22/
CTF/CTH
CTM-1SF40
CTM-
1SF75
CTM-1SF75H1
CTM-
2SF40
CTM-
2SF75
Lower limit temperature range [°C]
0
485
650
800
250
385
Upper limit temperature range [°C]
500
1050
1800
2200
800
1600
Lower alarm limit [°C]
(normally closed)
30
600
800
1200
350
500
Upper alarm limit [°C]
(normally open)
100
900
1400
1600
600
1200
Model
CTM-2SF75H1
CTM-3SF22
CTM-3SF33
CTM-3SF75H1
Lower limit temperature range [°C]
490
50
100
150
Upper limit temperature range [°C]
2000
400
600
1000
Lower alarm limit [°C]
(normally closed)
800
100
250
350
Upper alarm limit [°C]
(normally open)
1400
300
500
600
Model
CTM-3SF75H2 CTM-3SF75H3
CTP-7
CTP-3
Lower limit temperature range [°C]
200
250
0
50
Upper limit temperature range [°C]
1500
1800
710
400
Lower alarm limit [°C]
(normally closed)
550
750
30
200
Upper alarm limit [°C]
(normally open)
1000
1200
100
300
Smart Averaging means a dynamic average adaptation at high signal edges (activation via CompactConnect software only)