THERMAL-PROTECTION INSTRUCTIONS:
This vacuum cleaner is equipped with a thermal-protection device, which will interrupt vacuum
motor circuit automatically to prevent the motor from overheating. Air restrictions for an
extended period will result in the vacuum motor shutting down. If this occurs, press the switch
to turn the vacuum to the OFF position and wait a minimum of 5 minutes for the motor to cool to
a safe temperature. Be sure to determine the cause of overheating and rectify the problem
before using the vacuum cleaner again or it will continue to overheat and shut down. In some
instances the vacuum motor circuit is interrupted because of high motor temperature caused by
a dirty dust bag or an airway blockage. Please unplug the vacuum and check the inner paper
dust bag and airway. If the dust bag is too dirty and clogged, replace it with a new one. If an
airway is blocked, please remove the blockage before reuse. The motor can be restarted when
it is cool.
REPAIR SERVICE:
When servicing, use an authorized person only. Use only identical replacement parts.
PREPARATION FOR OPERATION:
Please refer to drawing 1
1)
Remove the cover (Item # 34) and cover seal ring (Item # 33), pull out the cloth filter bag
(Item # 31). Check to see that the filter guards (Item # 1, Item # 2 and Item # 3) have not
shifted during shipping.
2)
Install an inner paper dust bag (Item # 32) inside of the outer cloth filter bag (Item # 31). At
the beginning of each shift, the bags should be checked. Empty or replace as necessary.
3)
Note: never use a paper dust bag without the cloth dust bag.
4)
Place the cover seal ring (Item # 33) on the dust bag’s opening (Item # 32).
5)
Replace the cover (Item # 34) and clip the sunken edge of the cover tight by pushing
downward the cover clip (Item # 7).
6)
Push the connector tube (Item # 35) into the cover (Item # 34).
7)
Check the wear on the cord by the vacuum body and at the plug. Pass the power supply
cord (Item # 13) through the strip outside the left side of the waist belt (Item # 39).
8)
Fix the switch box under the sewn strap and knot the other strap around the switch box.
9)
Adjust the shoulder strap to allow the waist belt to be buckled around your waist.
10) Fasten the waist belt and chest belt snugly and make sure the weight is resting comfortably
on your hips. NOTE: The back-plate is adjustable up or down by removing the four screws
(Item # 27) that attach to the vacuum body (Item # 28).