25
25
OPERATOR MAINTENANCE
- Inspect manual function of the door every 3-months. Make sure that door runs smoothly. If door does not manually open
or close freely, have a qualified service person make repairs. Do not attempt to electrically operate a malfunctioning door.
- Every 3 months:
1. Verify that door area is kept clean. Remove any obstructions that would prevent proper door operation.
2. Check for any excessive slack in drive chain. If chain adjustment is required verify and adjust limit switches,
if
necessary.
3. Lubricate cams and limit shaft.
4. Verify that motor, reducer and operator runs smoothly and quietly. Verify that carriage runs smoothly on tracks.
- Every 6 months:
1. Verify tightness of all fasteners and set screws.
2. Verify that operator is properly secured.
3. Inspect manual disconnect.
- Every 12 months:
1. Perform a complete service check.
2. Verify that inside of control box is clean and that grounding wires, terminations and power terminations do
not show signs of corrosion.
3. Verify tightness of all terminal strip screws and electrical connections.
4. Verify power supply, voltage of input terminals during operation.
5. Verify that current consumption of operator corresponds to nameplate information.
WARNING
TO REDUCE THE RISK OF INJURY OR DEATH:
DO NOT ATTEMPT TO SERVICE THE OPERATOR UNLESS POWER SUPPLY HAS
BEEN DISCONNECTED
Summary of Contents for Pro-APTC
Page 1: ...installation instruction manual Serial Installation Date Wiring Diagram PRO APTC...
Page 28: ...MICANAN Commercial Door Opening Devices 3 1 2 4 5 6...
Page 29: ...MICANAN Commercial Door Opening Devices 4 1 2 3 5 6...
Page 30: ...MICANAN Commercial Door Opening Devices 4 1 2 3 5 6...
Page 31: ...Notes...