![Micanan Pro-APTC Installation And Instruction Manual Download Page 17](http://html1.mh-extra.com/html/micanan/pro-aptc/pro-aptc_installation-and-instruction-manual_1784287017.webp)
17
CONNECTION OF 110V RED AND GREEN TRAFFIC LIGHTS.
Refer to electrical schematic for connection of traffic lights
The operator is pre-wired to connect and activate 110V RED and GREEN traffic lights as per the following sequence:
• Green light is ON when the door is fully open.
• Red light is ON when door is in motion or stopped in any position other than fully open or fully closed. When “Delay
on close” timer is activated, Red light turns ON for the adjustable period of time set by the “DELAY ON CLOSE” dial
before the door closes. Please refer to “DELAY ON CLOSE SETUP” on page 16 of this manual.
• Traffic lights are OFF when door is fully closed.
The traffic lights can be connected to the apartment board as shown in the following diagram.
The following dry contacts are available on the apartment board for door status indication:
• Dry contact status for door opening status: Contact closes when door is opening.
• Dry contact status for door closing status: Contact closes when door is closing.
• Dry contact for door full open status: Contact closes when door is fully open.
• Dry contact for door full close status: Contact closes when door is fully closed.
MICANAN recommends the following setup and traffic light sequence in a typical apartment/condo installation:
• Mode of operation : TS (Set timer to close dial to desired value)
• Delay on close : Set the dial as required for the application
• Traffic lights are OFF when door is fully closed
• RED light turn ON upon activation of an open command and remains ON until door is fully open
• Green light turns ON and Red light turns OFF when door is fully open.
• Green light remain ON until timer to close timer is counting.
• “Delay on close” timer turns ON once the timer to close timer stops counting. At this time, Green light turns OFF and
Red light turns ON. Red light remains ON while “delay on close” timer is counting.
• Door closes after the Delay on close timer finishes counting. Red light is ON when door is closing and remains ON until
door is fully closes.
Summary of Contents for Pro-APTC
Page 1: ...installation instruction manual Serial Installation Date Wiring Diagram PRO APTC...
Page 28: ...MICANAN Commercial Door Opening Devices 3 1 2 4 5 6...
Page 29: ...MICANAN Commercial Door Opening Devices 4 1 2 3 5 6...
Page 30: ...MICANAN Commercial Door Opening Devices 4 1 2 3 5 6...
Page 31: ...Notes...