The MLC charging/holding stand is to be used with MICA ML lamps only. The battery will be charged
from empty to full in approximately four hours. The smart charging technology guarantees optimal
and safe charging in any situation.
1.
The red L1 light will be lit when the charging stand is attached to a correct supply voltage
(12- 24V).
2.
Place MICA ML lamp in the MLC charging stand. When charging begins, the orange L2 light
marked “charging” is illuminated. The lamp will be automatically turned off when it is placed in the
MLC charging stand. The ML-808 ATEX lamp can be charged at a temperature of 0°C ... +40°C only.
3.
When the battery is fully charged, the green L3 light marked “ready” is illuminated (and the
L2 light is turned off). At that time, the lamp is ready for use and the charging stand will switch to
maintenance charging mode.
4.
The lamp must always be stored in the charging stand in order to be ready for use at all
times. The MICA MLC quick charging stand will not overcharge the battery.
USING MICA ML-808 ATEX LAMP
Operating switch [A] of the Mica ML-808 ATEX lamp has three modes: LOW POWER → HIGH
POWER → OFF.
The operating time of lamp depends on the mode chosen. A fully charged battery will allow you
to work for approximately 4.5 hrs at High Power and 15 hrs at Low Power. If the lamp is used for
shorter periods of time, the total operating time will be slightly longer.
ML-808 ATEX Lamp has four indication LEDs at the back of the lamp indicating the charge state of
the battery.
Approximately 15-30 minutes before the battery is empty, the main light will begin to flash every 15
seconds.
Control electronics will automatically turn off the lamp prior to deep discharging of the battery. The
lamp can be turned on for short periods of time after the deep discharge prevention has operated,
but it will reduce the lifetime of the battery and is therefore not recommended.
When the lamp is not in use, it should be stored in the MICA MLC charging stand.
MICA ML-808 ATEX SAFETY INSTRUCTIONS
- Check that any part of the enclosure is not damaged and the lamp is functioning normally
- Cleaning and other necessary preparations must always be performed prior to moving into a
potentially explosive environment.
- Check that the classification of the lamp is suitable for the potentially explosive environment, in
which it is intended for use
- The charger must not be placed or lamp may not be charged in potentially explosive environments.
- The lamp must only be charged with the MICA MLC charger.
- The lamp may not be opened in a potentially explosive environment.
- If the lamp is not in good working order, remove it immediately from any potentially explosive
environments.
- If the type plate is unreadable or missing, the lamp is not valid for use in potentially explosive
environment.
LAMP MAINTENANCE:
- Always contact your local retailer for lamp servicing.