background image

L
N

( Yellow-green )

Installation Diagram

Firm ground or wall

1. Fix the lamp body on the 
base, and rotate the screws.

2. Select the installation place, 
and fix the base.

3. Adjust the illuminating 
angle, and tighten the screws.

180° 

1

3

2

Logarithmic dimming curve

Linear dimming curve

100

90

80

70

60

50

40

30

20

10

PWM duty(%)

50

60

70

80

90

100

Brightness(%)

10

20

30

40

Gamma=1.6

100

90

80

70

60

50

40

30

20

10

PWM duty(%)

50

60

70

80

90

100

Brightness(%)

10

20

30

40

Gamma=1.0

Dimming Curve Diagram

www.

ledbox.es

RDM

DMX

Connection Diagram

( Brown )
( Blue )

D+
D-
GND

( Yellow-green )

( Brown )
( Blue )

L
N

( Yellow-green )

( Brown )
( Blue )

IP66

IP Rate

Attention

1. This product should be debugged and installed by professionals.
2. Please check whether the input voltage meets the requirements of the product voltage range.
3. Before switching on the power, please ensure that all wiring is correct, so as not to cause 

damage to the lamps.

4. Please do not install the lamps on low-lying and easy inundated area.
5. If fault has occurred

non-professionals do not repair it without permission, otherwise the 

devices will be damaged.

Exit system mode: long press M button 1 second to exit. Or it will be self exit if there is no 

operation over 8 seconds.

Parameter 3: Digital display showing setting(show

or

) short press 

 button 

or 

 button to switch.

Under self-locking status, digital display always ON (low lighting showing). (Factory 
default parameter)

Under self-locking status, digital display OFF.

4. Restore factory default.

Under unlock status, long press

 

M

 

buttom 10 seconds until digital display show

               .

Attention: 

If the decoder is over 32pcs, or using the super long signal cable, you need DMX 

signal amplifier. Amplify signal cannot be over 5 times.

DMX512 Console

DMX512

Dimming

Panel