15. Surge (impact) immunity (see IEC61000-4-5): output / power supply 
2KV 1.2 / 50μs, performance criteria A; 
16.  Electrostatic  discharge  immunity  (see  IEC61000-4-2):  contact 

discharge 6KV, air discharge 8KV, performance criterion A; 

17.  Radio  frequency  electromagnetic  field  radiation  immunity  (see 

IEC61000-4-3): Test level 10V/m, performance criterion A; 

18.  Electrical  fast  transient  burst  immunity  (see  IEC61000-4-4):  signal 

line port: ± 2KV, auxiliary power port: ± 2KV, performance criterion 
A; 

19.  Conducted  immunity  of  RF  electromagnetic  field  induction  (see 

IEC61000-4-6): Test level 10V/m, performance criterion A. 

 

Instruction of Installation and Use

 

1.  The  product  has  adopted  structure  compliance  with  EN50022; 

suitable  for  DIN  rail  mounting  NS35/7.5,  NS35/15.  Installation 
steps are as following (please reference to dimensional drawing):   

Step  1:  Immobilize  one  side  of  product‘s  mounting  trough  to 

the DIN mounting rail; 

Step 2: Pull out the spring clasp; 
Step 3: Place whole mounting trough to the DIN mounting rail 

properly; 

Step 4: Release spring clasp to make sure the installation.   

2.  The  product  has  calibrated  before  out  of  factory.  After  correctly 
wiring,  it  can  be  powered  and  used  immediately.  But  for  further 
precise  signal  sampling,  user  need  to  warm-up  the  product  for  3 
minutes before use. 

a)

 

the  auxiliary  power  requires  isolation  voltage≥2000V

AC

,  DC 

current output ripple

10mV.   

b)

 

When  sensor  measuring  voltage  exceed  1000V,  it  needs 
dividing input voltage by using resistor which is provided by 
Weibo electronic. Different sensor uses special resistor. 

 
 

 

Summary of Contents for WBV412M05

Page 1: ...upplying WB Series Electric Isolated Sensor and Digital Electrical Sensor since 1989 USER MANUAL WBV412M05 AC voltage sensor www wbsensor com wbwm wbdz cn Tel 86 0816 2971265 Fax 86 0816 2281934 ISO9001 ISO14000 ISO18000 Certified ...

Page 2: ...amage Before working in the terminal strip area the equipment must be isolated Proper and safe operation of the equipment depends on appropriate shipping and handling proper storage installation and commissioning and on careful operation maintenance and servicing The operating manual for the equipment gives instructions for its installation commissioning and operation However the manual cannot cov...

Page 3: ... uses a special isolation module to measure the AC voltage in the grid and circuit in real time and convert it into DC voltage Uz output It has advantages of high precision high isolation low power consumption low drift wide temperature range and anti interference strong ability wide working power range and so on This product adopts card mounted structure terminal wiring easy installation three is...

Page 4: ...Over Load Capacity 2 times of nominal input continuous 8 Maximum Load output current 5mA 9 Auxiliary Power 9V 36V DC 10 Isolation Voltage Input Output 2500Vdc for 1 min Input power supply 2500Vdc for 1 min Output power supply 2500Vdc for 1min 11 Output Ripple 10mv 12 Drifting by Temperature 150 10 6 13 Ambient Temperature 25 70 14 Mounting DIN Rail 35mm Mount The undefined terminals in the diagram...

Page 5: ...criterion A Instruction of Installation and Use 1 The product has adopted structure compliance with EN50022 suitable for DIN rail mounting NS35 7 5 NS35 15 Installation steps are as following please reference to dimensional drawing Step 1 Immobilize one side of product s mounting trough to the DIN mounting rail Step 2 Pull out the spring clasp Step 3 Place whole mounting trough to the DIN mounting...

Page 6: ... the sensor for 3 minutes 4 using output monitoring meter V1 to measuring the output of signal power source instrument set a any input value which is within the measuring range of the sensor Vr for e g if input value is 100V the output is 0 5V the expected output value Vz should be calculated as Vz 5V 0V Vr 100V 5 using output monitoring meter V2 to measuring the output voltage V0 of the sensor th...

Page 7: ...iding bump and fall of the product 4 If the product has been using under the environment with strong magnetic field interference please pay attention to the shield of input wire and the output signal wire should be as short as possible For product intensive installation the space between each product should not be smaller than 10mm 5 Only use identified terminals 6 There is no lightning strike pre...

Reviews: