WB9128-1 Power Transducer (RS 485 Interface) 

Safety claim 

The information in the safety claim of the equipment documentation is intended to ensure that equipment is 

properly installed in order to maintain it in a condition. 

It is assumed that everyone who would be associated with the equipment should be familiar with the contents of 

that safety section, or this safety guide. 

When electrical equipment is in operation, dangerous voltages will be present in certain parts of the equipment (e.g. 

the input terminal). Failure to obverse warning notices, incorrect use, or improper use may endanger personnel and 

equipment and course personal injury or physical damage. 

Before working in the terminal strip area, the equipment must be isolated. 

Proper and safe operation of the equipment depends on appropriate shipping and handling, proper storage, 

installation and commissioning, and on careful operation, maintenance and servicing. 

The operating manual for the equipment gives instructions for its installation, commissioning, and operation. 

However, the manual cannot cover all conceivable circumstances or include detailed information on all topics. In 

the event of questions or specific problem, do not take any action without proper authorization. Contact the 

appropriate WB technical sales office and request the necessary information.   

 

Standard application 

1. Accuracy 

    Accurate degree is conformed to IEC688:1992 

2. Safety 

 2.1 Overload capability 

    Overload capability is conformed to IEC688:1992 

  2.2 Isolation voltage 

        Can be endured testing voltage is conformed to Q/72085584-0.1-2004 

  2.3 Insulation impedance 

    The insulation impedance is no less than 20M Ohm, is conformed to Q/72085584-0.1-2004     

3. Electromagnetic Capability   

    3.1 Electromagnetic field immunity test according to IEC 61000-4-3:1995 

3.2 Power frequency magnetic field immunity test according to IEC 61000-4-8:1993   

Product Description and Application   

WB9128-1 adopts special made isolation module, professional MCU controller and high speed data synchronizing 

sampling and processing technologies to isolate and convert active power of three-phase four-wired electric system 

or 3 phase 3 wire system    into RS485 bus and load independent output DC average current signal 4-20mA or 

0-20mA and dc voltage signal 0-5V or  1-5V; It has certain advantages of input/output isolation, high 

performance, low drifting by temperature, and low power consuming, etc. 

     

Product Dimensional Drawing (unit: mm)   

Mianyang Weibo Electronics Co.,Ltd 

www.wb-my.com 

2

Summary of Contents for WB9128-1

Page 1: ...Power Transducer RS 485 Interface 3 phase 3 wire 3 phase 4 wire www wb my com Tel 86 816 2971265 Fax 86 816 2281934 ISO9001 ISO14000 ISO18000 Certified Quality Warranty Any quality problem found in WB series products we offer One year free charge of repair the products and six months guaranteed free charge of change and return the products ...

Page 2: ...he event of questions or specific problem do not take any action without proper authorization Contact the appropriate WB technical sales office and request the necessary information Standard application 1 Accuracy Accurate degree is conformed to IEC688 1992 2 Safety 2 1 Overload capability Overload capability is conformed to IEC688 1992 2 2 Isolation voltage Can be endured testing voltage is confo...

Page 3: ...put 2 5V 2 5V 0 5V 1 5V 3V 2V DC Current 10mA 10mA 0 20mA 4 20mA 12mA 8mA 8 Output Parameters E R PQ C S Ua Ub Uc Uab Ubc Uac Ia Ib Ic Pa Pb Pc Qa Qb Qc Ca Cb CC Sa Sb Sc 9 Accuracy Grade Current voltage 0 2 reactive active power power factor 0 5 10 Response Time 200ms 11 Auxiliary Power Supply DC 12V DC 24V 12 Static Current 65mA 13 Operating Temperature 0 50 14 Communication Protocol Modbus RTU ...

Page 4: ...se Active Power 2 19 18 Pb B Phase Active Power 2 20 19 Pc C Phase Active Power 2 21 20 Qa A Phase Reactive Power 2 22 21 Qb B Phase Reactive Power 2 23 22 Qc C Phase Reactive Power 2 24 23 Ca A Phase Power Factor 2 25 24 Cb B Phase Power Factor 2 26 25 Cc C Phase Power Factor 2 27 26 Sa A Phase Apparent Power 2 28 27 Sc B Phase Apparent Power 2 29 28 Sc C Phase Apparent Power 2 Note 1 Output para...

Page 5: ...n 8 pin 7 pin 6 pin Analogue OUT2 RS485B OUT1 RS485A GND E Analogue RS485 Converter PC Series Port Power Supply Current direction 3 phase 4 wire Load Sensor Current Direction A C B A B C N 5 pin 3 pin 1pin 2 4 pin 11 Pin 10 Pin 9 Pin 8 Pin 7 Pin 6 Pin Analogue OUT2 RS485B OUT1 RS485A GND E Analogue RS485 Converter PC Series Port Power Supply Current Direction Current Direction Mianyang Weibo Elect...

Page 6: ...nt Rx Imax 0 0001 Unsigned Integer Ia Ib Ic Power Factor Rx 0 0001 Signed Integer COSφ COSφa COSφb COSφc Active Power Rx Umax Imax 0 0001 Signed Integer Pa Pb Pc Reactive Power Rx Umax Imax 0 0001 Signed Integer Qa Qb Qc Apparent Power Rx Umax Imax 0 0001 Unsigned Integer Sa Sb Sc Total Active Power Rx Umax Imax 3 0 0001 Signed Integer Psum Total Reactive Power Rx Umax Imax 3 0 0001 Signed Integer...

Page 7: ... Uab Ubc Uca Iz 4 16 Ux 4mA 20mA 0V 5V Ia Ic Uz 0 5 Ix 1V 5V Ia Ic Uz 1 4 Ix Ia 0mA 20mA Ia Ic Iz 0 20 Ix Ic 4mA 20mA Ia Ic Iz 4 16 Ix 3 Phase 4 wire Parameter Name Output Specifications Actual Output Value Calculation Formula Uz Rated Output Line Voltage V Iz Rated Output Current mA 0V 5V Psum Uz 0 5 Ux Ix 3 1V 5V Psum Uz 1 4 Ux Ix 3 2 5V 2 5V Psum Uz 2 5 2 5 Ux Ix 3 3V 2V Psum Uz 3 2 Ux Ix 3 Psu...

Page 8: ...0 20 Ix Ic 4mA 20mA Ia Ib Ic Iz 4 16 Ix 0V 5V Pa Pb Pc Uz 0 5 Ux Ix 1V 5V Pa Pb Pc Uz 1 4 Ux Ix 2 5V 2 5V Pa Pb Pc Uz 2 5 2 5 Ux Ix Pa 3V 2V Pa Pb Pc Uz 3 2 Ux Ix Pb 0mA 20mA Pa Pb Pc Iz 0 20 Ux Ix Pc 4mA 20mA Pa Pb Pc Iz 4 16 Ux Ix Pa Pb Pc Iz 10 10 Ux Ix 10mA 10mA Pa Pb Pc Iz 12 8 Ux Ix 12mA 8mA 0V 5V Qa Qb Qc Uz 0 5 Ux Ix 1V 5V Qa Qb Qc Uz 1 4 Ux Ix 2 5V 2 5V Qa Qb Qc Uz 2 5 2 5 Ux Ix Qa 3V 2V ...

Page 9: ...d interference please pay attention to the shield of input wire and the output signal wire should be as short as possible For product intensive installation the space between each product should not be smaller than 10mm 5 Only use identified terminals 6 There is no lightening strike prevention circuit design in this product For out door and hazardous environment using please add protective alterna...