6.4.1 Data Inquiry
6.4.1.1Data Inquiry Table List
This device supports the systems of 3 -phase 4 -wire, 3- phase 3- wire and single phase.
Inquiry Parameters show in the following table 4.
Table 4 Inquiry Parameters List
3 Phase 4 Wire
3 Phase 3 Wire
Single Phase
Current
1
:
PhaseV Zero Sequence Current
2
:
Phase C Average Current
1
:
Phase V Average Current
1
:
Phase-A Current
Voltage
1
:
Line V Frequency
2
:
Phase V Frequency
3
:
Line V Average Line Voltage
4
:
Phase VAverage Phase Voltage
5
:
Phase V Zero SequenceVolateg
1
:
Line V Frequency
2
:
Line V Average Line
Voltage
1
:
Phase V Frequency
Power
1
:
3 Phase Active Power + Total Active
Power
2
:
3 Phase Reactive Power + Total Reactive
Power
3
:
3 Phase Apparent Power + Total Apparent
4
:
3 Phase Power Total Power
Factor
1
:
Total Active Power
2
:
Total Reactive Power
3
:
Total Apparent Power
4
:
Total Power Factor
1
:
Total Active Power
2
:
Total Reactive Power
3
:
Total Apparent Power
4
:
Total Power Factor
Most Value
1
:
Voltage Maximum Value & Time
2
:
Current Maximum Value & Time
3
:
Total Active Power Maximum Value &
Time
4
:
Total Reactive Power Maximum Value &
Time
5
:
Total Apparent Power MaximumValue &
Time
6
:
Voltage Minimum Value & Time
7
:
Current Minimum Value & Time
8
:
Total Active Power Miniimum Value &
Time
9
:
Total Reactive Power Miniimum Value &
Time
10
:
Total Apparent Power MinimumValue &
Time
1
:
Voltage Maximum Value & Time
2
:
Current Maximum Value & Time
3
:
Total Active Power Maximum
Value & Time
4
:
Total Reactive Power Maximum
Value & Time
5
:
Total Apparent Power
MaximumValue & Time
6
:
Voltage Minimum Value & Time
7
:
Current Minimum Value & Time
8
:
Total Active Power Miniimum
Value & Time
9
:
Total Reactive Power Miniimum
Value & Time
10
:
Total Apparent Power
MinimumValue & Time
1
:
Voltage Maximum Value & Time
2
:
Current Maximum Value & Time
3
:
Total Active Power Maximum
Value & Time
4
:
Total Reactive Power Maximum
Value & Time
5
:
Total Apparent Power
MaximumValue & Time
6
:
Voltage Minimum Value & Time
7
:
Current Minimum Value & Time
8
:
Total Active Power Miniimum
Value & Time
9
:
Total Reactive Power Miniimum
Value & Time
10
:
Total Apparent Power
MinimumValue & Time
Harmonic
The first time press,can enter into Harmonic display interface, use
,
,
,
button to choose harmonic parameter
displayed;
The second time press, it is harmonic display interface. This time cannot choose harmonic parameter displayed. Press other
button can back from harmonic display interface, then enter into correspondent display interface.
Energy
1
:
Line V Fre Forward
Active Energy
2
:
Phase C Average C
1
:
Line V Fre
Forward Active Energy
2
:
Phase C Average C
1
:
Line V Fre
Forward Active Energy
2
:
Phase C Average C
Button
System
Parameter
-
18
-