22
Operator’s Manual
Preparing the Washer-Mister Mode
INLET WATER SUPPLY REQUIREMENTS
SUCTION FEED
1. Water supply hose should be a good grade of garden
hose with an I.D. of 3/8 in. (10mm) or 1/2 in. (13mm)
and be no longer than 10’ in length (3m).
Attempting to operate the washer in suction feed without
the correct hose will result in a lack of suction causing
rapid wear of packings, valves and bearings that will
dramatically shorten pump life. Symptoms include pump
shuddering and flattening of the supply hose.
2. Water supply (or chemical) tank should be clean and
located at or above the height of the unit’s water inlet.
3. In static draw situations, water flow rate (GPM) can
be increased by elevating the water supply tank or
changing to a larger inside diameter water supply hose.
IMPORTANT: Inlet water temperature must not be more
than 90° F (32° C). Damage to the pump
may result.
1. Remove shipping plug and install vented plug (A) on
pump.
2. Check oil in pump. With washer on level surface, the
oil should be 1/2 full, at the center of sight glass (B). If
necessary, add SAE30W non-detergent oil, so level is
1/2 full, at center of sight glass.
CHECK PUMP OIL
↑
B
↑
A
Summary of Contents for CM-1400-0MEC-DM