16
Description Connection terminals
1 & 2
Input terminal for the 230V/AC supply voltage of
the thermostat
3 & 4
Output terminal for connecting the consumer
unit
5
is not used
6 & 7
Input terminal for connecting the external
temperature sensor
Setting weekly programme (Auto mode)
Press the M button for 3 seconds to edit the Auto mode setting.
Switching times (event)
Symbols
Time
Temperature
Standard
Change
setting
Standard
Change
setting
Working
days
1
06:00
By turning
the
adjustment
wheel
20°C (68°F)
By turning
the
adjustment
wheel
2
08:00
15°C (59°F)
3
11:30
15°C (59°F)
4
12:30
15°C (59°F)
5
17:00
22°C (72°F)
6
22:00
15°C (59°F)
Weekend
1
06:00
20°C (68°F)
2
20:00
20°C (68°F)
Sensor error
Please select the operating mode of the sensor correctly. If the error E0/E1 is displayed, the thermostat
remains switched off until the error is corrected.
E0: Built-in sensor is short-circuited or disconnected.
E1: Floor sensor is short-circuited or disconnected