15
Open the settings menu:
- With the unit switched off, press the Mode button (button 1) for 3 seconds to enter the advanced
setting mode.
- Press the M key several times to change the menu item.
- The values can be changed by turning the dial.
- Press the power button to save and exit the advanced settings mode.
Code
Function
Default setting
01
Temperature calibration (-9.9 - 9.9°C / 9-9°F)
Standard: -3°C
02
Hysterese (0,5-10°C / 1-10°F)
Standard: +-1°C
03
Upper temperature limit (5-95°C / 41-99°F)
Standard: 50°C
04
Lower temperature limit (5-47°C / 41-99°F)
Standard: 5°C
05
Frost protection function (ON/OFF)
Standard: OFF
06
Temperature Unit (°C / °F)
Standard: °C
07
Sensor mode (IN: internal sensor only, OUT:
external sensor only, ALL: both sensors)
Standard: IN
08
Soil limiting temperature (20-90°C / 68-99°F)
Standard 35°C, for electric underfloor
heating we recommend max. 27°C
09
Setting for weekly programming
12345: 5/2 = Mon. - Fri. & Sat.+Sun.
123456: 6/1 = Mon. - Sat. & Sun.
1234567: 7/0 = Mon. - Sun.
Standard: 12345
10
Not relevant for heating operation
Standard: 00
11
Not relevant for heating operation
Standard: 0
12
Key lock (child lock):
00: Lock inactive when screen off / lock all
when lock on.
01: Lock active when screen off / lock
everything when lock on.
02: Lock active when screen off / lock all
functions except fan, up and down when lock
on
03: Lock active when screen off / lock all
except On/Off when fuse on
Standard: 00
13
Behaviour on power recovery:
00: remains switched off
01: is switched on
02: restores the previous state
Standard: 00
19
Factory settings
Press the Eco button for 3 sec.