Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx
Page 8 of 17
5.
Installation
The Flash Cure may be installed into either
an empty station or a print station. The Flash
Cure must be powered by a separate supply,
which must correspond to the technical data
of the unit. To control the unit the dryer
must be connected with the dryer connector
of the printing machine.
5.1.
Ambient Conditions
For the electrical equipment on the MHM Flash Cure, ambient conditions according to standard
IEC 60204 “Electrical Equipment of Industrial Machines” should be observed.
The following points should be observed in order to achieve efficient running and an optimum level
of production with the MHM Flash Cure:
1.
The premises, where the unit is to be operated, must be kept clean, dry and well-aired.
2.
The ambient temperature must not fall below +5° C or 45° C.
3.
Relative air humidity must not exceed 80 %.
4.
The mains supply must not exceed or fall below a tolerance of +/- 5 % of the required
voltage for the MHM Flash Cure. If this voltage stability cannot be guaranteed, the customer
must install a constant-voltage regulator to protect the unit against such fluctuations.
5.
Electricity supply should be sufficient with adequate fuse protection.
6.
Maximum installation altitude is 2000m above sea level.
Upon delivery of the MHM Flash Cure the consignment must be examined for
external damage immediately. In the case of any damages, they must be
documented and reported to Machines Highest Mechatronic GmbH within 24
hours.
Fragile spotlights! Handle the unit carefully.
Breakage due to improper handling is not covered by warranty.
Risk of electric shock! Avoid any contact with live components. Please
observe the general safety regulations for electrical connections when
connecting the mains supply to the MHM Flash Cure. It is important that a
qualified electrician should make all connections.