Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx
Page 16 of 17
8.
Maintenance of the Flash Cure
Task
Frequency
Comment/Action
Grills and fans cleaning
Daily
Clean the grills and fans.
Weekly cleaning.
Weekly
Open the unit and remove all lint and dust from inside
the unit and ensure that all the holes in the reflector
are clean and unobstructed.
Lamp cleaning.
Monthly
Clean the lamps when they are cold with a cloth
moistened with methylated spirits or denatured
alcohol.
9.
Accessories
9.1.
Temperature sensor
The temperature sensor is used to measure the temperature of the
ink and to optimize the drying time.
9.2.
Photocell
The photocell is used to start the Flash Cure after a print cycle
when the printing machine does not deliver an appropriate
start signal.
9.3.
Footswitch
With the footswitch, a manual start signal can be generated.
Safety precautions:
Unplug all mains power to the flash cure dryer.
If the flash cure was recently in operation ensure the unit has cooled down
before attempting to change the lamps.
The lamps are made of quartz glass and are therefore fragile –handle with
care and avoid contact with the glass.
It is important when either cleaning or changing a lamp that the quartz is not
touched by hands or fingers. If the lamps are touched then they must be cleaned
before switching on.