background image

13

14

Address (Hex)

Contents

Format Word Access

Range & Unit

0000

0000H

Integer

1

R

0013

000DH

Integer

1

0012

000CH

Integer

1

0011

000BH

Integer

1

0010

000AH

Integer

1

0004

0004H

Integer

1

0003

0003H

Integer

1

0002

0002H

Integer

1

0001

0001H

Integer

1

Measured value List

Address (Hex)

Contents

Format Word Access

Range & Unit

0512

0200H

1

R

0524

020CH

1

R

0523

020BH

1

R

0522

020AH

1

R

0521

0209H

1

R

0520

0208H

1

R

0519

0207H

1

R

0518

0206H

1

R

0517

0205H

1

R

0516

0204H

1

R

mA

0514

0202H

1

R

0513

0201H

1

R

0009

0009H

Integer

1

0008

0008H

Integer

1

0007

0007H

Integer

1

0006

0006H

Integer

1

0005

0005H

Integer

1

0515

0203H

1

R

Integer

mA

mA

mA

mA

1

R

0525

020DH

0019

0013H

Integer

1

0018

0012H

Integer

1

0017

0011H

Integer

1

0016

0010H

Integer

1

0015

000FH

Integer

1

0014

000EH

Integer

1

0531

0213H

1

R

0530

0212H

1

R

0529

0211H

1

R

0528

0210H

1

R

0526

020EH

1

R

0527

020FH

1

R

0537

0219H

1

R

0536

0218H

1

R

0535

0217H

1

R

0534

0216H

1

R

0532

0214H

1

R

0533

0215H

1

R

0543

021FH

1

R

0542

021EH

1

R

0541

021DH

1

R

0540

021CH

1

R

0538

021AH

1

R

0539

021BH

1

R

0549

0225H

1

R

0548

0224H

1

R

0547

0223H

1

R

0546

0222H

1

R

0544

0220H

1

R

0545

0221H

1

R

6.9 Data Register address: (integer format)

Parameter List

T(S) Time Delay

I(A) Pick up Current
Pre-Alarm threshold

Pre-Alarm Display

Frequency

Backlight saver

% and A Interchanging

Password

Device Address

Baud Rate

Data Frame

Clear record

Reversed

Reset

RTC Year

RTC Month

RTC Date

RTC Hour

RTC Minutes

RTC Second

R

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

0 - 50 (0.01Sec)

3 - 300 (0.01A)

5 - 100 (%)

0(no) - 19(sec)

0 - 1 (note)

0(no) - 99(min)
0(no) - 19(sec)

000 - 999

1 - 255

0 - 5 (note)

0 - 3 (note)

0 - 1 (1:Reset)

0 - 1 (1:Clear)

0 - 100 (note)

1 - 12 (note)

1 - 31 (note)

0 - 23 (note)
0 - 59 (note)
0 - 59 (note)

Note: 

Frequency

Baud rate

Data Frame

RTC setting

0: 50Hz, 1: 60Hz

0: 1200, 1: 2400, 2: 4800, 3: 9600, 4: 19200, 5: 38400

0: n,8,2 ; 1: o,8,1 ; 2: e,8,1 ; 3: n,8,1

No effect if RTC is not enable

Descriptions

Index

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

%

1: Pre-Alarm

1: Pickup exceeded

1: Trip

1: Abnormal

note

note

note

note

note

note

note

note

note

note

note

note

note

note

note

note

note

note

note

note

note

note

note

note

note

note

note

note

(+2000)

(+2000)

(+2000)

(+2000)

Leakage current (A)

Leakage current (%)

Pre-Alarm Status

Sensing Status

Tripping Status

ZCT Status

REC. 1 Trip Type

REC. 1 Trip Current

REC. 2 Trip Type

REC. 2 Trip Current

REC. 3 Trip Type

REC. 3 Trip Current

REC. 4 Trip Type

REC. 4 Trip Current

REC. 1 Trip Year

REC. 1 Trip Month

REC. 1 Trip Day

REC. 1 Trip Hour

REC. 1 Trip Minutes

REC. 1 Trip Sec

REC. 2 Trip Year

REC. 2 Trip Month

REC. 2 Trip Day

REC. 2 Trip Hour

REC. 2 Trip Minutes

REC. 2 Trip Sec

REC. 3 Trip Year

REC. 3 Trip Month

REC. 3 Trip Day

REC. 3 Trip Hour

REC. 3 Trip Minutes

REC. 3 Trip Sec

REC. 4 Trip Year

REC. 4 Trip Month

REC. 4 Trip Day

REC. 4 Trip Hour

REC. 4 Trip Minutes

REC. 4 Trip Sec

Note: 

Tripping Type

0: No Rec, 1: Fault current Trip, 2: Test button Trip

Tripping time record

RTC : Trip Time refer to the current time

 

Elapse time: Trip Time refer to the time different from the current time

 

Descriptions

Index

Summary of Contents for EL D Series

Page 1: ...m m m TRIP PROG COM S A 25 50 75 TEST RESET A T S I A ZCT REC RTC Elapse time Operation Manual EL xx D series Mun Hean Singapore Pte Ltd 02 2020 ...

Page 2: ...etting Records Functions keys Configuration Screen switching Trip LED On Relay trip Flashing ZCT open circuit ZCT shown on screen TEST button Press 2 times TRIP and Pre alarm contact energise and Trip LED ON shown on screen RESET button Press once to reset TRIP LED OFF shown on screen 1 2 Terminals Power supply RS 485 Communication ZCT current input TRIP contact Pre Alarm Remote reset contact Sele...

Page 3: ...tting 1A The display show I A it indicates setting values other display type will not show Real time Leakage current Press to toggle between and A mA Activate the SCR function for Auto scrolling the two displays or mA REC Record memory show on and T S and I A is off ZCT Detect open circuit Trip LED flashing COM RS485 enable ON if it is communicating RESET Press to reset the relay TEST Press 2 time...

Page 4: ... m m m TRIP PROG COM S A 25 50 75 TEST RESET A T S I A ZCT REC m m m TRIP PROG COM S A 25 50 75 TEST RESET A T S I A ZCT REC m m m TRIP PROG COM S A 25 50 75 TEST RESET A T S I A ZCT REC m m m TRIP PROG COM S A 25 50 75 TEST RESET A T S I A ZCT REC 3 Display and Buttons Functions Displayed only with RTC function RTC value display Leakage current and Setting value Leakage current is constantly disp...

Page 5: ... ZCT REC Alternate delay display setting 4 Setting and Buttons function 4 1 Setting menu 100 as master password Default password 000 Wrong password will show display return to main page When in setting page TEST button is disable Password 0 Password 0 Setting Main Menu T S Time Delay Range 0 0 5sec I A Current Threshold Range 0 03 3 00A 03D 0 5 30 0A 30D Pre Alarm setting Range 5 100 Time delay as...

Page 6: ... ZCT REC m m m TRIP PROG COM S A 25 50 75 TEST RESET A T S I A ZCT REC Only show when RTC is enable RTC Main Menu Year Range 000 100 Display 2000 2100 Month Range 01 12 Day Range 1 31 Hour Range 00 23 Minutes Range 00 59 Seconds Range 0 59 PROG PROG PROG PROG 4 2 Buttons functions Descriptions Main Menu Enter Sub menu Switching between Main Menu Return to previous page No effect Reset Sub Menu Ent...

Page 7: ...l Fast Transient According to IEC 61000 4 4 Withstanding impulse volatge According to IEC 61000 4 5 Connection Plug in terminal block Weight About 0 2 kg excluding ZCT Electromagnetic wave Non operation for ratio frequency at 130 180MHz and 400 500MHz by walkie talkie of 5W Volatge dips and short interruptions According to IEC 61000 4 11 5 Specifications EL 30D 0 3 30 0A in step of 0 1A 0 01 0 5se...

Page 8: ... 50 0 01Sec 3 300 0 01A 5 100 0 no 19 sec 0 1 note 0 no 99 min 0 no 19 sec 000 999 1 255 0 5 note 0 3 note 0 1 1 Reset 0 1 1 Clear 0 100 note 1 12 note 1 31 note 0 23 note 0 59 note 0 59 note Note Frequency Baud rate Data Frame RTC setting 0 50Hz 1 60Hz 0 1200 1 2400 2 4800 3 9600 4 19200 5 38400 0 n 8 2 1 o 8 1 2 e 8 1 3 n 8 1 No effect if RTC is not enable Descriptions Index Integer Integer Inte...

Reviews: