It is recommended to carefully read the instructions for use described in this manual before using the instrument.

Keep this manual near the instrument for any quick consultation by the operators!

The Manufacturer declines all responsibility for malfunctions and/or consequences arising from incorrect operations by the User.

Even partial reproduction of this manual in any form is prohibited without the written authorization of the Manufacturer.
The Manufacturer reserves the right to make improvements or changes to its instruments at any time and without notice.

Introduction

Introduction

Congratulations on purchasing this machine.
This manual supplied with the machine and the remaining installation material, which varies according to the configuration of the kit or the 

estimate prepared, provides important instructions for the construction of a properly functioning system, for its operation and maintenance. 
We remind you that this manual is an integral part of the instrument and contains the indications for a correct use of the same.
We therefore invite you to carefully read the instructions for use before using the instrument, to properly instruct the operators and to keep 

it carefully for any future consultation.
These good standards will be the guarantee to obtain excellent performance and reliability from the instrument over time.
IMPORTANT: use 

MGF

MGF

 pump oil; the use of different lubricants could reduce the performance of the pump or damage it, even irreversibly. 

NEVER USE THE PUMP WITHOUT OIL !!!!

General informations

General informations

SERVICE

For any form of technical assistance you can contact us in one of the following ways:

telephone: +39 0521 818301
fax: +39 0521 818202
email: 

[email protected]

We will serve you as soon as possible.
The shipment of material under repair must be previously authorized by means of the RMA form (binding condition for the collection of any 

goods under repair).

WARRANTY TERM

The product warranty covers any manufacturing defect for a period of time equal to one (1) year from the date of manufacture for 

products purchased with invoice, 2 years for products purchased by private individuals.
The following clauses expressly exclude the product from guarantee:

Consumables insofar as the malfunction is caused by normal wear of the parts

Damage caused by improper operation

Bad maintenance

Machine tampering or modification

The company excludes from its responsibility any indirect damage, damage caused to people and things by defects and machine downtime, 

incorrect use, lack of maintenance.

2

MGF

MGF

 srl –– Via Chico Mendes, 8 – 43058 Sorbolo Mezzani (PR) Italy – Tel. +39 0521-818301 Fax: +39 0521-818202

e-mail: [email protected] – 

www.mgftools.com

 – 

www.nebulife.it

 – 

www.nebulizzare.com

Summary of Contents for 930456

Page 1: ...age 1 MGF MGF srl Via Chico Mendes 8 43058 Sorbolo Mezzani PR Italy Tel 39 0521 818301 Fax 39 0521 818202 e mail info mgftools com www mgftools com www nebulife it www nebulizzare com Art 930456 930457 930487 930488 Dual Stage Vacuum Pump User Manual Rev 2 dated 07 03 2022 ...

Page 2: ...ll be the guarantee to obtain excellent performance and reliability from the instrument over time IMPORTANT use MGF MGF pump oil the use of different lubricants could reduce the performance of the pump or damage it even irreversibly NEVER USE THE PUMP WITHOUT OIL General informations General informations SERVICE For any form of technical assistance you can contact us in one of the following ways t...

Page 3: ...nt Before disconnecting a pipe check that all the valves are closed this will prevent the refrigerant from being dispersed into the atmosphere and avoid dangerous gas leaks In any case avoid to disperse the refrigerant in the environment This practice in addition to reducing refrigerant pollution facilitates the search for any gas leaks Do not fill containers beyond 75 of their maximum capacity Al...

Page 4: ... the sight glass The level should be at the same level as the oil level line on the sight glass Add oil if necessary Note When the pump is running the oil level should be at the same level as the line on the sight glass Insufficient filling will result in poor vacuum performance Overfilling can cause oil to leak out of the drain 2 Suction tube Connect the suction pipe to the pump and to the manome...

Page 5: ...unning Do not operate the pump for more than 20 seconds using this method 3 When the flow of oil has stopped tilt the pump forward to drain the residual oil 4 Replace the OIL DRAIN cap Remove the exhaust fitting and fill the reservoir with new vacuum pump oil until the oil just shows at the bottom of the sight glass The approximate oil capacity of the pump is 180 800ml reference the technical data...

Page 6: ...nza mgftools com N Descripton N Descripton 1 Fan cover 14 Inlet fitting 2 Cross screw 15 Trestle 3 Fan 16 Screw 4 Motor cover 17 Rotary vane 5 Cross screw 18 Cap board 6 Bearing 19 Exhaust fitting 6 MGF MGF srl Via Chico Mendes 8 43058 Sorbolo Mezzani PR Italy Tel 39 0521 818301 Fax 39 0521 818202 e mail info mgftools com www mgftools com www nebulife it www nebulizzare com ...

Page 7: ...ree You can confirm leakage by monitoring the vacuum with a thermistor gauge while applying vacuum pump oil at connections or suspected leak points The vacuum will improve briefly while the oil is sealing the leak 2 Be sure the pump oil is clean A badly contaminated pump may require several oil flushes 3 Be sure the oil is at the proper level For maximum pump operation the oil must be even with OI...

Page 8: ...bility to directive 2004 108 EC as regards the safety of electrical equipment the directive 2006 95 EC as far as hazardous materials are concerned they comply with the 2011 65 EC standard as regards electrical waste they comply with the 2012 19 EC standard as regards pressure vessels it complies with standard 97 23 EC MGF MGF srl 8 MGF MGF srl Via Chico Mendes 8 43058 Sorbolo Mezzani PR Italy Tel ...