5. Performance & Product Specifications

5—1

Table 5a.

Esprit Models 3 and 4 Rack UPS Specifications

Item

Specification

Comment

Output VA

2880/4000

Output W

2016/3150

Surge protection, joule rating

420 joules per system

Each battery cabinet adds 210 joules

Waveform

Stepped approximation of sine wave

Pseudo-sine wave on back-up only

Nominal input voltage

120 VAC (opt. 100 or 127 VAC) 

+10%, -15%

Maximum input voltage (VAC)

140 

Low voltage transfer (VAC)

102

Adjustable to 96 

Low line return (VAC)

109 

Adjustable to 99 

High line transfer (VAC)

132

High line return (VAC)

126 

Input current (A)

24/33 maximum

Input frequency (HZ)

50 or 60 + or  - 2.5 HZ

Auto-select at start-up

Input protection

Customer provided, branch

Transfer time

4-8 ms.

To or from battery

Overload protection, line mode 

Output disabled at >120% load

Overload protection, battery mode Output disabled at >120% load
Efficiency, on utility

>98%

Efficiency, on battery

>93%

Battery mode voltage

120 VAC + or - 5% (120 VAC mode)

Battery life expectancy

3-5 years

Output frequency regulation

N or  - 0.5 HZ

On battery

Battery mode output protection

Electronic current limit

Self-protected

Battery 

12 each 5 Ah

144 VDC nominal bus

Maximum charge current

0.7 A

With 100% discharge

Float voltage

2.25 VDC/cell (162 VDC)

Backup time

5 minutes

100% load

Battery protection

Current limiting fuses 

1 internal, 1 w/extended battery

Recharge time

8 hrs.. to 90%, 4 hrs.. to 80%

Full discharge

Battery charger ripple current

0.05C maximum

Low battery alarm level

1.75 v/cell, no load (126 VDC)

Low battery shutdown level

1.65 v/cell, full load (119 VDC)

Faulty battery alarm level

1.8 v/cell (130 VDC)

Low battery alarm level

3 minutes before end of discharge

Charger protection 

Overload, current protected

Max. # of extended batteries

Unlimited

Controls

Start, stop, alarm reset switches

Communications 

RS232 or USB + two contact 

HID on RS232 or USB 

closures included

(selectable RS232 or USB)

Temperature

0-40 C

Air flow

30 CFM on battery

Heat: ESP030   40-141W

Humidity

0-95% non-condensing

Heat: ESP040   60-211W

Noise

45 dBA maximum

Summary of Contents for Esprit 3

Page 1: ...Made in USA Made in USA Slim Line Rack UPS User s Manual Models 3 4 www mgeups com...

Page 2: ...UPS SYSTEMS 1660 Scenic Avenue Costa Mesa CA 92626 714 557 1636 www mgeups com Revision History Esprit Rack UPS User s Manual 86 153301 03 Copyright 2000 MGE UPS Systems All rights reserved Printed in...

Page 3: ...cuit protection Do not place Esprit near water or in an environment of excessive humidity Do not allow liquids or foreign objects to get inside Esprit Do not block air vents in front on top or on bott...

Page 4: ...ear rubber gloves boots and safety glasses Determine if the battery is inadvertently grounded Please dispose of the packaging in accordance with applicable laws Federal Communication Commission FCC St...

Page 5: ...packing the UPS 3 1 3C Placement of the UPS 3 1 Rack Mounting 3 1 3D Optional Accessories 3 1 3E Connecting the Optional Extended Battery 3 2 3F Disconnecting the UPS Battery to Take Out of Service 3...

Page 6: ...Fine MGE Products inside back cover Figures 2a Rear View of Models 3 and 4 With Rack Kit and Extended Batteries 2 2 2b Optional Rack Mounting Kit 2 2 2c Typical Front Views of Models 3 4 Extended Batt...

Page 7: ...ing are also provided in this mode The UPS instantly transfers the load to the battery when a power failure occurs If the power returns before the battery is exhausted the operation returns to normal...

Page 8: ...1 2...

Page 9: ...and fastest Other communications optional communications communications possible Network based power Multiple server shutdown and management software supervision Web management New standard for web Ea...

Page 10: ...of electric shock even when input power is removed Do not remove cover No user serviceable parts inside Refer to qualified service personnel In Ue Eing Entrada Do not disconnect under load Vac In Ue E...

Page 11: ...it upright and then remove the packing material Save packaging for future shipment of UPS to MGE for recycling 3C Placement of the UPS Choose a location out of direct sunlight with adequate ventilatio...

Page 12: ...will need the RS232 serial port or a USB Universal Serial Bus port The connection will be made between your computer s serial or USB port and the serial or USB port on the rear of the UPS module as sh...

Page 13: ...ectrician Table 3a UPS Wiring Information Figure 3c AC Line Cord of the Extended Battery Model Plug Amp rating 3 L5 30 30 4 5 50 50 3I Connecting the Loads Utilize the receptacles on the rear of the U...

Page 14: ...o the UPS 3J Solution Pac Software Solution Pac software allows you to interface your computer with the UPS The software is loaded on your computer and through the communication port can access and re...

Page 15: ...iagnostics as well as check utility power After depressing the green On button and starting your UPS for the first time you will hear an audible beep confirming the button has been depressed and your...

Page 16: ...Utility power is present and within specification limits On Inverter On Mode Utility power is available but is outside specification limits On Flashes Battery Low A low battery warning will sound Ack...

Page 17: ...an the UPS itself 4 Output The UPS is capable of The UPS is heavily The UPS is slightly over loaded Overload supporting the load overloaded Automatic The UPS will continue to sup yellow connected to i...

Page 18: ...if it is active If a new alarm fault is detected after a silence operation the beeper will be re activated to issue the new alert This button sequence can be thought of as an alarm fault acknowledge f...

Page 19: ...lem is corrected Fault LED and Charge Charger Problem Warning The battery system may not be LED flashes until alarm long short long short beep plugged into an AC source or is acknowledged or problem t...

Page 20: ...4 6...

Page 21: ...mode voltage 120 VAC or 5 120 VAC mode Battery life expectancy 3 5 years Output frequency regulation Nominal or 0 5 HZ On battery Battery mode output protection Electronic current limit Self protected...

Page 22: ...X 19 Weight 65 70 lbs total MTBF 200K hours Sizing Guide and Battery Runtimes In minutes 0 62 PF Unix Server 1 2 3 4 server servers servers servers PC Server 1 2 3 4 5 6 7 8 server servers servers ser...

Page 23: ...The AC PRESENT indicator blinks slowly during the time that the Esprit is in configuration mode To exit configuration mode press and hold both top and bottom buttons again The AC PRESENT indicator wi...

Page 24: ...he options that can be changed by the user in configuration mode and shows which front panel indicators will be on for each option Option Indicators Number Fault Batt Fail Charge Overload Option affec...

Page 25: ...4 SlimLine Internal only 1 2 3 4 5 6 7 Indicators Option On illuminated Option Off dark Options 3 4 Operating voltage selection These two options select the nominal operating voltage of the UPS as sh...

Page 26: ...attery contact without actually running the Esprit battery down To clear the User Test Fault set this option to OFF or follow the Alarm Clear procedure Press and hold the top button Option 8 Limit run...

Page 27: ...default ON setting the Esprit will analyze the input power when it is turned on and configure itself to operate at the proper frequency 50 or 60 Hz If utility power is not present when the Esprit is...

Page 28: ...he POIT is enabled the UPS will power up the load from utility power then briefly switch to battery power approximately 5 7 seconds after it is powered up The UPS runs on battery for only 3 5 seconds...

Page 29: ...utility power due to disconnection of the safety ground 2 Allow the UPS to run on battery power for 1 minute Monitor the UPS for any fault LEDs and if none are observed return power to UPS and log res...

Page 30: ...all 1 714 557 1636 M F 6 00 A M to 5 00 P M PST Ask for a return goods authorization for free UPS or battery recycling MGE does not cover return freight charges for recycling and will not accept items...

Page 31: ...l socket repair as remains on even though specification required line voltage is present UPS beeps occasionally UPS is on battery None UPS is protecting your system UPS does not provide Battery capaci...

Page 32: ...Notes 8 2...

Page 33: ...0 2200 VA 780 2200 VA EX UPS EX Rack UPS 700 3000 VA 700 3000 VA Call MGE for many more power solutions 714 557 1636 or 800 523 0142 US MGE GREEN SWEEP Call MGE to return your UPS for free recycling t...

Page 34: ...MGE UPS SYSTEMS USA headquarters 1660 Scenic Avenue Costa Mesa CA 92626 tel 800 523 0142 714 557 1636 fax 714 557 9788 www mgeups com...

Reviews: