OPERATING INSTRUCTIONS
Pneumatic Carton Stapler for coiled staples
MERO 18 P + MERO 22 P
Page:
6
Mod.:
804
ET 675, 676
Page 6 of 6 04.05.2018
resulting from this undue use. Any risk of damage is borne solely by the user.
Use as directed also means observing the operating, servicing and maintenance conditions laid down by
the manufacturer of the tool.
The stapler may only be used, maintained and repaired by persons who are familiar with it and have been
advised of the dangers.
The relevant accident prevention regulations as well as other generally recognized industrial safety and
medical regulations must be observed.
Unauthorized modifications to this stapler or the use of spare parts or staples which are not original parts
from the manufacturer exclude any liability of the manufacturer for any resultant damage.
3.10 General Instructions
When not in use disconnect air supply and remove all staples.
Important - General Instructions
It is the customer’s responsibility to have all operators and service
personnel read and understand this manual.
MG
tools are ruggedly built for long, dependable operation.
Details about sa
fety as well as all necessary information for the tool’s
proper care and general maintenance are contained in this book.
Safety rules
NEVER exceed the recommended maximum pressure for the tool
(normally 6 bars).
DO NOT attempt to use a defective stapler.
NEVER load the stapler until you are ready to use it
DO NOT reload when you release a stapling operation
Only operate the tool when in contact with the carton surface.
At all times keep hands clear of base of machine whilst activating trigger.
Do not attempt to staple on to hard surface.
NEVER USE oxygen, combustible gases or high pressure compressed gas
tanks as air supply for the tool
Always disconnect air supply and empty magazine before: work breaks,
changing parts, servicing tools or clearing a jammed staple, storing tool at
the end of the day
ALWAYS utilise couplers on the compressor side of the air supply
system (couplers when disconnected automatically shut off the flow of
air)
4 Maintenance and Personal Safety Instructions (training, education)
Operation and usage of the stapler is only allowed to specially advised and trained persons.
For maintenance: Always disconnect the tool from the air supply.
For repair use only original spare parts from the manufacturer (s. spare parts list).
The following actions/inspections have to be regularly accomplished by specially advised and trained
persons:
Clean stapler regularly
Oil all movable parts weekly (no oil containing graphite!).
Check the pneumatic operating unit. Refill oil and remove water if necessary.
The pneumatic operating unit should be adjusted to one oil drop per 40-50 machine cycles.
Remark: Advised and trained persons are those who have the education and the experience to use
stapling tools. They have also knowledge of governmental safety and accident prevention instructions
and technical guidelines as DIN, etc. They can also judge function and operating reliability of staplers.
5 Shut down instructions
If the stapler will not be used disconnect air supply and remove all staples.