SAFETY NOTICES AND TERMINOLOGY USED 

 

 

Warning! 

 

 

Warning

!”  Denotes a potentially dangerous situation. Failure to comply with these 

notices can result in serious injury or even death. 
 

 

 

Caution! 

 

 

Caution

!”  These notices show a situation that can result in minor injury or damage to 

property if not complied with. 
 

 

 

Please note! 

 

 

Please note

!”  Points out situations where ignoring the safety notice can negatively 

affect the result of work being carried out and damage the equipment. 

 

 

Important! 
 

Important

!”  Notices are helpful hints and other particularly useful pieces of information. 

They do not indicate a potentially dangerous or harmful situation.

 

 

 

 

 

DESIGNATED USE 

 

  

 - The viewing or examining under the microscope of objects by looking through the 

eyeglass. 

 - The illuminating of the working area. 

 

  

The MEZZO may only be used in conjunction with PUK – precision welders. 

 

  

The MEZZO may only be used when it is correctly connected.  
 

Any other application of the appliance other than the above stated, is prohibited. 
 
It is prohibited to use this apparatus out of doors. Use only in dry surroundings! 

 

 

 

 

 

 

INTRODUCTION 

 

  

Arc welding without protective equipment is dangerous and can lead to a painful 
inflammation of the cornea. It can also lead to an irreversible clouding of the eye lenses 
(cataract).  
 
The MEZZO with its integrated LCD glare protection filter offers a reliable safeguard 
against these dangers. It provides continuous protection against UV/IR-rays, as well as 
sparks and splashes, both in the filters clear setting (Luminescence DIN3) as well as in 
its dark setting (Obscurity DIN11). 
 
The filter is constructed so that a dazzling from the glare of the electric arc is avoided. 
Shortly before an electric arc is fired, the electronic circuitry of the PUK 3s, switches the 
filter automatically from its clear setting (Luminescence DIN3) to its dark setting 
(Obscurity DIN11). The filter then returns to the clear setting again immediately after the 
electric arc is extinguished. 
 
The MEZZO may only be used in conjunction with a PUK precision welding devices. 

Summary of Contents for PUK 3s

Page 1: ...y qualified personnel and then only for its designated use and in accordance with the guidelines here within The manufacturer accepts no responsibility and is in no way liable for damage caused by imp...

Page 2: ...etting the viewing distance 7 5 3 Focussing 7 5 4 Dioptre settings 8 6 CARE AND MAINTENANCE 6 1 Maintenance of the optical components 8 6 2 Maintenance of the electrical components 9 7 TROUBLE SHOOTIN...

Page 3: ...her application of the appliance other than the above stated is prohibited It is prohibited to use this apparatus out of doors Use only in dry surroundings 2 INTRODUCTION Arc welding without protectiv...

Page 4: ...must be shut down and removed from the power supply it must also be secured against accidental re operation or activation It is likely and can be expected that a safe operation of the device is no lo...

Page 5: ...ut together using excessive force Mount the bearing rod 11 to the base plate 13 using the bolt that is included tighten it with an open ended spanner Place upright on a clean flat and stable surface S...

Page 6: ...n using these models it is necessary to use a transformer plug This is available as an optional extra Plug in the transformer plug into a suitable mains socket WARNING before connecting the stereo mic...

Page 7: ...hat when both hands are resting on the hand rests 14 the work piece can easily be guided to the tip of the electrode Here remember to first correctly position the hand piece in the supporting arm Swit...

Page 8: ...t eye open look through the left eye piece and adjust the focus by turning the dioptre adjustment 2 on the left eye piece tube 3 until the viewed object is in focus 6 CARE AND MAINTENENCE Under normal...

Page 9: ...it flush with the underside of the supporting arm 7 TROUBLE SHOOTING PROBLEM CAUSE SOLUTION 7 1 PROBLEMS WITH ELECTRICAL COMPONENTS A The LED light doesn t work Cable is not attached Switch on the cor...

Page 10: ...h the other 13 Always hold the microscope upright 8 TECHNICAL DATA 8 1 TECHNICAL INFORMATION MICROSCOPE LCD glare protection filter and LED light module for use only in conjunction with PUK precision...

Page 11: ...posal system 10 EG CONFORMITY DECLARATION The Manufacturer Lampert Werktechnik GmbH Ettlebener Str 27 97440 Werneck Germany declares herewith that the following product Welding microscope with integra...

Reviews: