Slurry Pump
WH16AA1LA00EN_01E.DOC
JAN
04-W08
Care and maintenance
2/3
9.4.2
Lubrication interval
The bearings may be re-greased with any lithium-based grease that conforms to the
specification detailed in Table 9.4.1-1.
The lubrication interval depends upon the shaft speed and the bearing operating
temperature, as shown in Table 9.4.2-1.
Frame Grease
Pump speed (rpm)
Size
(g)
500
800
1000
1500
2000
2500
3000
FR250
20
2275
1500
1000
650
500
350
250
FR300
25
1600
1300
900
600
400
300
200
FR400
35
1250
1000
750
500
350
-
-
FR500
50
1250
900
550
350
-
-
-
FR600
70
1250
800
350
200
-
-
-
FR750
90
900
550
200
-
-
-
-
Table 9.4.2-1 Recommended lubrication interval for bearings @ 70
°
C (hours)
The pump should initially be re-greased after 250 running hours or the recommended
interval (whichever is less), unless stored for longer than 12 months before start-up, in
which case the long-term storage instructions should be followed (See section 1.2).
Multiply above lubrication intervals by the factors given below if the normal bearing
operating temperature (measured on the rim of the bearing end cover) differs from 70 °C.
Temperature (°C)
50
60
70
80
90
100
110
120
Multiplier
2.5
1.6
1.0
0.65
0.40
0.25
0.15
0.10
While the bearings and specified grease have a maximum operating temperature of
120°C, it is recommended that temperatures above 100 °C be avoided. However,
transient temperatures between 100 °C and 120 °C are acceptable immediately following
re-greasing.