The following steps describe how to properly install the cables for an IBM 46xx Stratos
S
application. The scanner
must
then
be configured to match the host’s IBM 46xx parameters. Cable installation alone
does not
guarantee that the Stratos
S
will
communicate properly with the host system.
Configuration bar codes are located in the MetroSelect Configuration Guide
(
MLPN
00-02407
x
) and the
MS2
xxx
Stratos Series Configuration Addendum (
MLPN
00-02034
x
).
1. Turn off the host system.
2. Plug the 10-pin RJ45 end of the IBM interface cable (
MLPN
57-57212
x
-N-3) into the 10-pin socket labeled
Scanner Host
46xx
, on the bottom of the Stratos
S
. Refer to Figure on page 21.
3. Connect the other end of the IBM cable to communication port 9 on the host device.
Before continuing verify that the IBM cable is connected to the appropriate interface socket on the scanner. An
incorrect cable connection can cause communication problems or potential damage to the scanner and/or terminal.
Manufacturers Note:
Plugging the scanner into the serial port of the host device does not guarantee that scanned
information will appear at the host device. A software driver and correct configuration settings are also required for
proper communication to occur.
4. Plug the external power supply (
MLPN
46-002xx) into the 3-pin Molex socket labeled,
DC Power
In
, on the bottom of the
Stratos
S
.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet
should be located near the equipment and be easily accessible.
Metrologic recommends using a switched AC outlet. The switch should be located on the operator’s side of the
checkout counter in close proximity to the Stratos
S
to facilitate calibration and service of the unit.
5. Connect AC power to the transformer. If the AC outlet is equipped with an on/off switch, turn the power on.
6. Turn on the host system.
7. Configure the Stratos
S
to match the host system’s IBM 46xx parameters.
Refer to the MS2
xxx
Stratos Series Configuration Addendum (
MLPN
00-02034
x
) under
Scanner Configuration
Bar Codes:
IBM 3
rd
Generation Communication Defaults
and
IBM 3
rd
Generation Protocols.
Additional general configuration bar codes can be found in the MetroSelect Configuration Guide
(
MLPN
00-02407
x
)
.