16
I
NSTALLATION
C
ABLE
I
NSTALLATION
(I
NTERFACE
S
PECIFIC
)
RS232
The following steps describe how to properly install the cables for an RS232 Stratos
S
application. The scanner
must
then be
configured to match the host’s RS232 parameters. Cable installation alone
does not
guarantee that the Stratos
S
will
communicate properly with the host system.
Configuration bar codes are located in the MetroSelect Configuration Guide
(
MLPN
00-02407
x
) and the
MS2
xxx
Stratos Series Configuration Addendum (
MLPN
00-02034
x
).
1. Turn off the host system.
2. Plug the 10-pin RJ45 end of the RS232 interface cable (
MLPN
57-57210
x
-N-3)
into the 10-pin socket labeled
Scanner Host RS232,
on the bottom of the SratosS. Refer to figure
on page 17.
3. Connect the other end of the RS232 cable to the proper communication port on the host device.
Before continuing, verify that the RS232 interface cable is connected to the appropriate interface socket on the
scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner
and/or terminal.
4. Plug the external power supply (
MLPN
46-002
xx
) into the 3-pin Molex socket labeled, DC Power In, on the bottom of the
Stratos
S
.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet.
The outlet should be located near the equipment and be easily accessible.
Metrologic recommends using a switched AC outlet. The switch should be located on the operator’s side of the
checkout counter in close proximity to the Stratos
S
to facilitate calibration and service of the unit.
5. Connect AC power to the transformer. If the AC outlet is equipped with an on/off switch, turn the power on.
6. Turn on the host system.
7. Scan the recall
Recall Defaults
bar code.
The
Recall Defaults
bar code is located in the MetroSelect Configuration Guide (
MLPN
00-02407
x)
, under
Need to
Start Over
.
8. Configure the Stratos
S
to match the host system’s RS232 parameters.
Refer to the MetroSelect Configuration Guide (
MLPN
00-02407
x
) under
Section G: RS232
for enabling RS232
Mode (scan the
recall defaults
bar code first)
.
Summary of Contents for StratosS MS2221
Page 1: ...METROLOGIC INSTRUMENTS INC MS2221 MS2222 StratosS Scanner Installation and User s Guide...
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ...December 2006 Printed in the USA 0 0 0 2 2 6 8 B...