background image

 

 

23

I

NSTALLATION

 

 

C

ABLE 

I

NSTALLATION 

(I

NTERFACE 

S

PECIFIC

)

 

 

OCIA 

 

 

 

 
 
 

xx**  Specifies international connection.  See the Base Kit Components and Optional 

Accessories section of this guide for a complete listing. 

 

        See power source caution statement on pages 8 or 11 of this manual.

 

 

 

Figure 22. OCIA Cable Installation Schematic 

 
 
 

Summary of Contents for StratosS MS2221

Page 1: ...METROLOGIC INSTRUMENTS INC MS2221 MS2222 StratosS Scanner Installation and User s Guide...

Page 2: ...rior written consent except by reviewer who may quote brief passages in a review or provided for in the Copyright Act of 1976 Trademarks Metrologic is a registered trademark of Metrologic Instruments...

Page 3: ...sions 10 Connector Panel 10 Caution and Serial Number Labels 11 INSTALLATION Quick Installation Outline 12 Site Requirements 12 Vertical Clearance 12 Ventilation and Spacing 12 Service Access 12 Power...

Page 4: ...ti Function Button 36 Startup 37 Power Up Test Mode 37 Configuration Mode 37 MAINTENANCE Horizontal Scan Window Replacement 38 Vertical Scan Window Replacement 39 Daily Maintenance 39 TROUBLESHOOTING...

Page 5: ...gue and stress The StratosS is equipped with a multitude of standard features including StratosSCAN 5 sided 360 scanning that minimizes product orientation StratosSPHERE Decoding software that reads p...

Page 6: ...utor or call Metrologic s Customer Service Department at 1 800 ID METRO or 1 800 436 3876 OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES Part Description 57 57210x N 3 RS232 Interface Cable Straight 3 7 m...

Page 7: ...ety and or scanner performance differences To change window type the scanner must be returned to the manufacturer for reconfiguration 46 00232 Vertical Window 46 00233 Diamonex Platter Compact 46 0029...

Page 8: ...REMOVAL No hardware or tools are required to remove the platter see Figure 3 Refer to the Maintenance section of this manual for additional information on platter replacement See caution statement on...

Page 9: ...ettings Blue Laser ON Ready to Scan Indicators LED White Good Read Decoding Mechanical MS2221 L x W x H 399 mm 15 7 Length 292 mm 11 5 Width 130 mm 5 12 Tower Height MS2222 L x W x H 353 mm 13 9 Lengt...

Page 10: ...Steel Platter with Diamonex or Sapphire Horizontal Window Laser Aperture 7 Flow Direction Indicators 8 Platter Support Bumpers see page 38 9 Optional Product Weight Roll Bar Platter Lift Handle Optio...

Page 11: ...ors for scale and display communication cabling The use of these connections is dependent on the specific manufacturer of the scale being integrated Please refer to the custom Scale Installation Guide...

Page 12: ...n compliance with applicable standards all circuits connected to the scanner must meet the requirements for SELV Safety Extra Low Voltage according to EN IEC 60950 1 To maintain compliance with standa...

Page 13: ...Finger Recesses for Lifting Located Under Platter 5 High Impact Window Frame Vertical Window Laser Aperture 6 Replaceable Stainless Steel Platter with Diamonex or Sapphire Horizontal Window Laser Aper...

Page 14: ...10 BASE MODEL CHARACTERISTICS MS2222 Scanner Dimensions Figure 10 MS2222 Dimensions Connector Panel Figure 11 MS2222 Connectors Specifications are subject to change without notice...

Page 15: ...in compliance with applicable standards all circuits connected to the scanner must meet the requirements for SELV Safety Extra Low Voltage according to EN IEC 60950 1 To maintain compliance with stand...

Page 16: ...routing and installing the cable s and power supply make sure you leave access so that these components may be swapped easily without the need to remove the unit from the checkout counter When changi...

Page 17: ...foam around the unit Important Do not turn the unit upside down or tilt the unit onto its side while removing the shipping foam The platter is not attached to the unit and can fall off 5 Lift the plat...

Page 18: ...14 INSTALLATION INSTALLING THE UNIT IN THE COUNTER MS2221 Mounting Diagram Figure 17 MS2221 Mounting Diagram Specifications are subject to change without notice...

Page 19: ...15 INSTALLATION INSTALLING THE UNIT IN THE COUNTER MS2222 Mounting Diagram Figure 18 MS2222 Mounting Diagram Specifications are subject to change without notice...

Page 20: ...correct cable connection can cause communication problems or potential damage to the scanner and or terminal 4 Plug the external power supply MLPN 46 002xx into the 3 pin Molex socket labeled DC Power...

Page 21: ...xx Specifies international connection See the Base Kit Components and Optional Accessories section of this guide for a complete listing See power source caution statement on pages 8 or 11 of this man...

Page 22: ...ot guarantee that scanned information will appear at the host A software driver and correct configuration setting are also required for proper communication to occur 4 Plug the external power supply M...

Page 23: ...oSelect Configuration Guide MLPN 00 02407x under Low Speed USB Any low speed USB warnings may be disregarded when utilizing these codes for a Full Speed USB StratosS scanner Step 7 must be completed b...

Page 24: ...ng the scanner into the serial port of the host device does not guarantee that scanned information will appear at the host device A software driver and correct configuration settings are also required...

Page 25: ...IBM 46XX xx Specifies international connection See the Base Kit Components and Optional Accessories section of this guide for a complete listing See power source caution statement on pages 8 or 11 of...

Page 26: ...able connection can cause communication problems or potential damage to the scanner and or terminal Manufacturers Note Plugging the scanner into the serial port of the host device does not guarantee t...

Page 27: ...OCIA xx Specifies international connection See the Base Kit Components and Optional Accessories section of this guide for a complete listing See power source caution statement on pages 8 or 11 of thi...

Page 28: ...dary scanner see figure on page 25 3 Connect the angled end of the RS232 AUX cable MLPN 57 57099x 3 into the 10 pin socket labeled Aux RS232 In on the bottom of the StratosS Important The StratosS ser...

Page 29: ...LATION CABLE INSTALLATION SECONDARY METROLOGIC SCANNER See Aux power notes on page 24 See power source caution statement on pages 8 or 11 of this manual Figure 23 Secondary Scanner Cable Installation...

Page 30: ...1 SW2 switches 1 and 6 set to ON All StratosS models have a connector labeled EAS In on the bottom of the unit Metrologic has an optional EAS cable MLPN 52 52511x available for purchase for connection...

Page 31: ...27 SCANNER OPERATION SCAN ZONE Figure 26 Checker Side 13 mil Figure 27 Horizontal Left Right 13 mil Specifications are subject to change without notice...

Page 32: ...28 SCANNER OPERATION SCAN ZONE Figure 28 Horizontal Direct 13 mil Figure 29 Vertical Direct 13 mil Specifications are subject to change without notice...

Page 33: ...ted by the IR in the activation area shown below in grey will cause the scanner to exit the power save mode The motor will restart automatically and the laser will turn back on preparing the scanner f...

Page 34: ...usly beeps three times The white and blue LEDs will continue to flash until the unit exits configuration mode Upon exiting configuration mode the scanner will beep three times and the white LED will s...

Page 35: ...e type of error Failure Modes Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced a laser subsystem failure The scanner will try up to 3 times to correct the failure c...

Page 36: ...guration memory did not agree with the data last saved Default configuration data is then used and the scanner continues operating This error is also accompanied by 3 beeps This error will remain duri...

Page 37: ...e right horizontal laser 2 is also in error the horizontal scanning subsystem will be shut down and this error code will remain on the Diagnostic Indicators 24 LASER 1 VERTICAL HIGH CURRENT WARNING Th...

Page 38: ...error persists the vertical scanning subsystem will be shut down and this error code will remain on the Diagnostic Indicators 32 MOTOR 2 HORIZONTAL ERROR The motor in the horizontal scanning subsystem...

Page 39: ...d motor OFF after a configured period of non use Any movement detected by the IR will wake the scanner from the power save mode see Figure 30 on page 29 This mode s wake time is slightly longer due to...

Page 40: ...tone is also selectable 9 9 9 9 7 4 Next Volume The Multi Function Button Figure 33 The Multi Function Button Changing the Beeper Volume A short 3 second depression and the beeper volume will change T...

Page 41: ...xamples of the types of tests performed at power up 1 Memory tests 2 Hardware setup tests 3 Motor tests 4 Laser tests 5 Configuration tests 6 Interface tests These tests are also performed on a period...

Page 42: ...e new platter s window The unit will not function properly if the protective film is not removed Figure 37 Platter Horizontal Scan Window Replacement See replacement parts on page 3 If the platter on...

Page 43: ...ical Scan Window Replacement DAILY MAINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code Therefore the horizontal and vertical output windows will need occasional cleaning...

Page 44: ...he beeper is disabled Enable the beeper No volume is selected Select a volume The unit powers up but does not beep No tone is selected Select a tone The unit is trying to scan a particular symbology t...

Page 45: ...t satisfy the configured criteria Verify that the bar code that is being scanned falls into the criteria Typical of Non UPC EAN codes The scanner defaults to a minimum of 4 character bar code The bar...

Page 46: ...iguration Bar Codes Auxiliary Port Quick Start for a Secondary Metrologic Scanner RS232 DEMONSTRATION PROGRAM If an RS232 scanner is not communicating with your IBM compatible PC key in the following...

Page 47: ...9 Code 128 9 9 9 9 Code 93 9 9 9 9 Codabar 9 9 9 9 Interleaved 2 of 5 ITF 9 9 9 9 MOD 10 Check on ITF 9 9 9 9 Code 11 9 9 9 9 Code 39 9 9 9 9 Full ASCII Code 39 9 9 9 9 MOD 43 CD on Code 39 9 9 9 9 T...

Page 48: ...9 9 Three Beeps on Timeout 9 9 9 9 No Beeps on Timeout 9 9 9 9 Fast Beep 9 9 9 9 Beep Twice on Supplements 9 9 9 9 No Beeps on Timeout 9 9 9 9 5 Retries Before Timeout 9 9 9 9 Timeout In 2 secs 9 9 9...

Page 49: ...9 Convert UPC A to EAN 13 9 9 9 9 Transmit UPC A Check Digit 9 9 9 9 Transmit UPC A Number System 9 9 9 9 Transmit UPC A Manufacturers ID 9 9 9 9 Transmit UPC A Item ID 9 9 9 9 UPC E Enable 9 9 9 9 E...

Page 50: ...op Bits 2 9 RTS CTS Enabled 9 Message RTS 9 Character RTS 9 ACK NAK 9 O N Handshaking 9 Host Bell Cancel 9 Xon Xoff 9 No Transmit Without DTR Present 9 French PC Terminal Emulation 9 D E Disable Comma...

Page 51: ...onfigurable Prefix for Code Types 9 9 Configurable Suffix for Code Types 9 9 Configurable Code Length Locks 7 avail 9 9 9 Code Selects 7 avail 9 9 9 Transmit High Priority Code at Timeout 9 9 9 Random...

Page 52: ...9 9 Bookland 979 Supplements 9 9 9 9 Convert 979 to ISBN 9 9 9 9 Convert 290 to ISBN 9 9 9 9 Reformat ISBN 9 9 9 9 Add EAN Article ID 9 9 9 9 Transmit ISBN EAN Check Digit 9 9 9 9 977 Supplements 2 d...

Page 53: ...x Parity none 9 9 9 9 Aux Data Bits 8 9 9 9 9 Aux Stop Bits 1 9 9 9 9 Aux Character RTS 9 9 9 9 Aux Message RTS 9 9 9 9 Aux Ack Nak 9 9 9 9 Aux Xon Xoff 9 9 9 9 Aux D E Commands 9 9 9 9 Aux M O Comman...

Page 54: ...2 Interface 3 RS232 Receive 4 Reserved for RS232 Interface 4 RS232 RTS Out 5 Reserved for RS232 Interface 5 RS232 CTS In 6 Reserved for RS232 Interface 6 RS232 DTR In 7 No Connect 7 No Connect 8 Reser...

Page 55: ...e display to the M2221 do not exceed the following current restrictions 12V 0 7A max 5V 0 2A max Figure 40 Scale Ready Connector Layout Scale Display Data In Scale Data to Display from the Load Cell I...

Page 56: ...6 DSR Output 7 CTS Input 8 RTS Output 9 No Connect 9 Pin D Type Connector Full Speed USB Cable MLPN 57 57201x N 3 or MLPN 57 57227x N 3 Pin Function 1 PC 5V USB 2 Data 3 Data 4 Ground Locking Type A 5...

Page 57: ...gnal Ground 2 RS232 from Aux Secondary Scanner 3 RS232 to Aux Secondary Scanner 4 RTS from Aux Secondary Scanner 5 CTS to Aux Secondary Scanner 6 8 No Connect 9 5VDC Transformer Direct 10 Shield Groun...

Page 58: ...lient ne doit en aucun cas essayer d entretenir lui m me le scanner ou le laser Ne regardez jamais directement le rayon laser m me si vous croyez que le scanner est inactif N ouvrez jamais le scanner...

Page 59: ...ons to this equipment could void the user s authority to operate this device This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may n...

Page 60: ...inst harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause...

Page 61: ...ct into any mechanical electrical or computer system The warranty is void if the case of Product is opened by anyone other than Metrologic s repair department or authorized repair centers THIS LIMITED...

Page 62: ...r by implication estoppel or otherwise under any METROLOGIC or third party intellectual property rights whether or not such third party rights are licensed to METROLOGIC including any third party pate...

Page 63: ...e error codes 32 34 indicator 30 modes 30 31 finger recess 4 6 9 flow 6 9 frame 9 function 40 47 48 50 53 G ground 50 53 H host 30 31 37 40 42 43 49 I IBM 46xx 43 49 indicators 5 audible 30 36 37 40 4...

Page 64: ...50 53 secondary scanner 24 25 SELV 16 23 specifications 5 storage 5 switch 26 T test 37 tone 6 9 30 36 transformer see power troubleshooting 40 42 U USB 43 49 V ventilation 5 12 visual 31 voltage 2 5...

Page 65: ......

Page 66: ......

Page 67: ......

Page 68: ...December 2006 Printed in the USA 0 0 0 2 2 6 8 B...

Reviews: