782 IC Column

Thermostat

782 IC Column Thermostat

Metrohm

Metrohm

8.782.1003 Instructions for Use

01.03.2000 / dö

Summary of Contents for 782 IC

Page 1: ...au Switzerland Tel 41 71 353 85 85 Fax 41 71 353 89 01 Internet www metrohm ch E Mail info metrohm ch 782 IC Column Thermostat 782 IC Column Thermostat Metrohm Metrohm 8 782 1003 Instructions for Use...

Page 2: ...tion 7 2 1 4 Arrangement of the instruments 7 2 2 Mains connection 8 2 2 1 Setting the mains voltage 8 2 2 2 Fuses 9 2 2 3 Mains cable and mains connection 9 2 2 4 Switching the instrument on off 9 2...

Page 3: ...Table of contents 782 IC Column Thermostat II List of figures Fig 1 Front of 782 IC Column Thermostat 2 Fig 2 Rear of 782 IC Column Thermostat 3 Fig 3 Setting the mains voltage 9...

Page 4: ...trol unit and the IC Column Heater column heating element which is placed inside the 733 IC Separation Center or the 761 Compact IC The separating col umn inserted in the column heating element is bro...

Page 5: ...Front of 782 IC Column Thermostat 1 1 Key PGM Program key without function 4 4 Key EXIT Exit key without function 2 2 Key Down Key to lower the set temperature 5 5 Current temperature Digital display...

Page 6: ...ARNING Fire Hazard with the same type and rating of fuse For continued protection replace only Fig 2 Rear of 782 IC Column Thermostat 7 7 Fuse holder Changing the fuses see section 2 2 10 10 Serial nu...

Page 7: ...C Column Ther mostat provide a comprehensive overview of the installation startup procedure operation and technical specifications of this instrument The Instructions for Use are organized as follows...

Page 8: ...m parameter or entry value of 761 OK Button of 761 Hazard This symbol draws attention to a possible danger to life or of injury if the associated directions are not followed correctly Warning This sym...

Page 9: ...tat is connected to the power supply the instrument must not be opened nor must parts be removed from it otherwise there is a danger of coming into contact with compo nents which are live Hence always...

Page 10: ...s only they assure transport of the instrument free from damage 2 1 2 Check After receipt immediately check whether the shipment is complete and has arrived without damage compare with delivery note a...

Page 11: ...s cable from mains connection plug 12 12 of the 782 IC Column Thermostat 2 Remove fuse holder Using a screwdriver loosen fuse holder 7 7 and take out com pletely 3 Change mains voltage Completely remo...

Page 12: ...rland 6 2122 040 with plug CEE 7 VII Germany 6 2133 070 with plug NEMA 5 15 USA which are three cored and fitted with a plug with an earthing pin If a different plug has to be fitted the yellow green...

Page 13: ...ect column to injector Mount a 6 2744 014 compression fitting on each side of the 6 1836 000 preheating capillary procedure see section 2 5 3 of 732 733 Instructions for Use Connect the long free end...

Page 14: ...ompact IC Proceed as follows to insert the 2 782 0100 IC Column Heater into the 761 Compact IC 1 Switch off all instruments Switch off 782 IC Column Thermostat and 761 Compact IC using the mains switc...

Page 15: ...ctor block 46 46 with suppressor module Screw outlet end of separating column 81 81 to suppressor inlet capillary 96 96 using a 6 2744 010 compression fitting 6 Insert column in IC Column Heater Remov...

Page 16: ...The desired heating temperature is set using the two keys 2 2 and 3 3 A single pressing of these keys increases or de creases the temperature value shown in the lower display 5 5 in green by 0 1 C con...

Page 17: ...3 Operation 782 IC Column Thermostat 14...

Page 18: ...ow Safety specifications Construction Testing According to IEC 1010 EN 61010 UL 3101 1 protection class 1 degree of protection IP40 Safety directions The Instructions for Use include information and w...

Page 19: ...5 45 C at 20 80 atmospheric humidity Storage transport 40 70 C Housing Material of cover Polyurethane rigid foam PUR with fire protection for fire class UL94VO CFC free Material of base Steel enamelle...

Page 20: ...lder to fix the IC Column Heater in the inner compartment of the 733 IC Separation Center or 761 Compact IC Opening d 37 mm Set of 2 1 6 2122 0X0 Mains cable to customer s specifications Cable socket...

Page 21: ...the absence of guaranteed features the purchaser has no rights or claims except those mentioned above If damage of the packaging is evident on receipt of a consignment or if the goods show signs of t...

Page 22: ...EN 50081 1 2 Electromagnetic compatibility basic specification Emitted Interference EN 50082 1 2 Electromagnetic compatibility basic specification Interference Immunity EN 61010 Safety requirements f...

Page 23: ...e testing according to the standards IEC61326 EN61326 NAMUR EN55011 EN55022 EN 50081 1 2 IEC61000 4 2 EN61000 4 2 class 4 IEC61000 4 4 EN1000 4 4 class 4 IEC61000 4 11 EN61000 4 11 IEC61000 4 14 EN610...

Page 24: ...ion valve 68 68 Connect preheating capillary 10 Inlet capillary 45 45 Mount 12 Inlet capillary 82 82 Mount 10 Installation 7 Instructions for Use 8 782 1003 4 Instrument description 1 Introduction 1 K...

Page 25: ...x 782 IC Column Thermostat 22 System validation 20 T Technical data 15 Temperature range 15 Transport 7 16 Transport damage 7 18 V Voltage selection insert 8 8 Change fuses 8 Figure 3 9 W Warning 5 Wa...