9
2.2. Storage
The unit must be stored and transported free of water and within its packaging .
Transport and storage may take place at temperatures between -10 °C and +50 °C . If
the unit has been transported or stored at sub-zero temperatures the unit should be
left at room temperatures for 24 hours before commissioning .
3. POSITIONING
• It is recommended that the split box is installed in a room with existing floor
drainage, most suitably in a utility room or boiler room .
• The bracket for the split box is mounted to the wall by use of appropriate screws .
• Route pipes so they are not fixed to an internal wall that backs on to a bedroom or
living room .
• Ensure that there is approx . 800 mm free space in front of and sufficient space
above the product for any future service . Ensure that there is sufficient space
above the machine for pipework and valves .