MI 3300 PAT Demoboard
Demonstration tables information
11
5.4. IEC cord
Simulates
Error value
Error off
Error on
Simulation between contacts
Measurement taken
Error off
Error on
Error 1
Loose contact of PE conductor
Error value
0,02 Ω
0,84 Ω
PE pin on socket (1) and PE pin on
socket (2)
Earth Bond
0,02 Ω
0,84 Ω
Error 2
Insulation fault
Error value
>20 MΩ
106 kΩ
L and PE pins on socket (2)
Insulation 500 V DC
>20 MΩ
0,106 MΩ
Error 3
Crossed L and N wire
Polarity
/
L, N crossed
Polarity
Polarity
/
“L, N crossed”
Table 5.3: Description of simulated faults / relevant tests
Note:
For safety reasons there is a serial resistance between L/N pins of socket 1 and socket
2. Some test instruments can therefore return a fail on the Polarity test !