MI 3200 TeraOhm 10 kV
Specifications
44
Display range Test voltage (V)
Resolution
Accuracy
0
9999 V
1 V
(3 % of r 3 V)
10 kV
0.1 kV
(3 % of reading)
Withstanding voltage DC
DC test voltage:
Voltage value:
Any value within 500V and 10kV.
Accuracy:
-0 / +10 % + 20 V.
Display range Test voltage (V)
Resolution
Accuracy
0
9999 V
1 V
(3 % of r 3 V)
10 kV
0.1 kV
(3 % of reading)
Leakage current
Display range Itrigg (mA)
Resolution
Accuracy
0.000
0.009
1
A
(3 % of r 3 digits)
0.01
5.50
10
A
(3 % of reading)
Voltage
Voltage AC or DC
Display range External Voltage (V)
Resolution
Accuracy
0
600
1 V
(3 % of r 4 V)
Frequency of external voltage
Display range (Hz)
Resolution
Accuracy
0 and 45
65
0.1 Hz
0.2 Hz
Note:
-
for frequency between 0 and 45 Hz
displayed <45 Hz
-
for frequency over 65 Hz
displayed >65 Hz
Input resistance: 3 M
10 %
Capacitance
Measuring range C: 50
F*
Display range C
Resolution
Accuracy
0.0
99.9 nF
0.1 nF
(5 % of r 2 digits)
100
999 nF
1 nF
1.00
50.00
F
10 nF
*Full-scale value of capacitance is defined according to the following equation:
C
FS
= 10
F * U
test
[kV]