A 1636 

DC/AC Current clamp  

 

1  Symbols and Warnings 

 
To  ensure  a  high  level  of  operator's  safety  during  using  of  A  1636  DC/AC  current  clamps  the 
following warnings has to be considered: 
 
 
 

 

 Do not apply around or remove from hazardous live conductors. 

 

 

!

 

De-energize the installation on which the current is measured or adopt safe 

operating procedures when working on hazardous live installations, during 
application and removal of A 1636 current clamps.   

 

 

!

 

Do not use the current clamp if any damage is noticed! 

 

 

!

 

Consider all generally known precautions in order to avoid risk of electric shock 

while dealing with electric installations! 

 

!

 

Do not extend hands over safety barrier to prevent of electric shock! Only 

handles are allowed to be touched during measurement! 

 

 

!

 Symbol on the current clamp indicates the possibility of a hazardous live 

condition if the operator ignores the required safety measures. 

 

 

!

 

If the current clamps are used in a manner not specified in this Instruction 

manual, the provided protection can be impaired!

 

 

 

 

!

 

Only a competent, authorized person is allowed to carry out service intervention! 

 

 

!

 Do not connect clamp output elsewhere than to Metrel PQ Analyzers (MI 2892, MI 

2885, MI 2883). 

 

 

 Current clamps are protected by double insulation.  

Summary of Contents for A 1636

Page 1: ...DC AC Current clamp 2000A A 1636 Instruction manual Version 1 2 Code no 20 752 824...

Page 2: ...rel metrel si 2012 METREL Mark on your equipment certifies that this equipment meets the requirements of the EU European Union concerning safety and electromagnetic compatibility regulations No part o...

Page 3: ...Current clamp 3 Table of contents 1 SYMBOLS AND WARNINGS 4 2 DESCRIPTION OF CURRENT CLAMP 5 3 OPERATION INSTRUCTIONS 6 4 MAINTENANCE 7 INSPECTION 7 CLEANING 7 SERVICE AND CALIBRATION 7 5 TECHNICAL SPE...

Page 4: ...rally known precautions in order to avoid risk of electric shock while dealing with electric installations Do not extend hands over safety barrier to prevent of electric shock Only handles are allowed...

Page 5: ...gn no need to disconnect the measured circuits non contact safe and fast It can be connected with phase detection analyzer industrial control equipment data recorder oscilloscope harmonic analyzer ele...

Page 6: ...and the output of sensor is 1mV 1A it means that when the input current is 1A the ratio metric voltage is1mV 1 Clamp 2 Up cover 3 Trigger Open and close the clamp 4 Indicate of positive input AC curr...

Page 7: ...ave them to dry totally before using it Do not use liquids based on petrol or hydrocarbons Do not spill cleaning liquid over the current clamps To clean jaw cut surfaces use slightly oiled soft cloth...

Page 8: ...magnetic field to the measurement of AC current Output connection Standard connection Red wire positive output Yellow wire negative output Output Wire Length 2m Measured Wire Position Approximately in...

Reviews: