1. Outdoor unit installation position
2. Outdoor unit installation
Notice
To avoid ventilation short, the outdoor unit discharged air should not return when installation.
Please keep enough space around the outdoor unit for repair. Right and wrong means as below:
2.1.To get enough air for ventilation of the unit, the installation position should be with good
ventilation.
2.2.The installation position can hold the outdoor unit without noise and shake.
2.3.No sunlight to the unit. Set an awning if necessary.
2.4.The water from rain and defrosting can be discharged in the installation position.
2.5.The unit will not be covered by snow in the installation position.
2.6.The discharged air will not face strong air in the installation position.
2.7.Be sure the noise caused by the unit ventilation and operation will not affect the neighbor.
2.8.The installation position will not be affected by garbage, oil and mist.
2.9.The outdoor unit will be damaged under the condition with oil, salt and sulfide air.
Wrong
Right
MACON
III. Installation Notice
Multi-Function Air To Water Heat Pump