4.1.4 Overloading
If the mixer is moving e.g. kneading dough, this is not due to errors or overloading.
In case of overloading the electronic variator will reduce the current to the motor and stop
it.
In case of stop due to overloading, turn the rotary button back to neutral position, and the
mixer can be started again.
If the motor stops after long time of operation, and cannot be started immediately after,
the thermosensor of the motor has switched off the current, and the mixer needs to cool
down before it can be re-started. This protects the mixer from being destroyed.
The mixer contains two thermal cut-outs, which automatically reconnect in case of previ-
ous disconnection by the thermosensor.
4.2 After use
4.2.1 Cleaning
•
Remove bowl and tools.
•
Wash the bowl and the tools in hot water and detergent / degreaser / disinfectant.
Rinse with pure water and dry.
Do not spray water on the mixer
Tools and bowl can be cleaned in dishwasher.
•
Wipe the housing of the planetary gear, the bayonet shaft and the safety guard. Use
a damp sponge and a detergent / disinfectant. Rinse the parts with sponge and pure-
water.
•
Check that the various parts have been cleaned thoroughly.
•
Do not use abrasive detergents, which could scratch the surface.
•
Use detergents suited for use on aluminium and plastic (polycarbonate).
4.2.2 Periodic service
The mixer requires no maintenance (motor and bearings for the mechanical parts are
greased for life).