13.2.2009
Rev. 4.0
Adjustment instructions
10
Fault messages
(in case the alarms are enabled). If an alarm occurs, the LEDs will flash
on the display. Press the upper button (1) to display the alarm codes.
Alarm code
Action
A1
High temperature alarm
A2
Low temperature alarm
A4
Door alarm
A15
Alarm signal (DI input)
A45
Standby mode (r12 or DI input)
A59
Cleaning (DI input)
E1
Fault in controller
E27
Sensor error on S5
E29
Sensor error on Sair
E30
Sensor error on Saux