4.
Using the appliance
4.1. Prior to use
• Clean the cabinet prior to use. For further details we refer to the maintenance section.
• Leave the installation to stand for at least 2 hours before switching on the cabinet.
• Plug into a grounded power socket.
4.2. Thermostat
Key combination
To lock or unlock the keyboard
To enter in programming mode
Return to room temperature display
Icons and functions
On
Compressor enabled
Flashing
Compressor delay enabled
On
Light output enabled
On
Fans output enabled
Flashing
Fans delay after defrosting
On
Measurement unit
Flashing
Programming mode
On
Energy saving mode active
On
An alarm condition is present
Flashing
Start-up operations are pending
Start-up operations lasts about 30 sec. after powering on device. At the end of this phase, the alarm icon
will switch off if no alarm is active. Wait for the end of this interval of time before doing modifi cations on