05.10.2012
METOS Maxiglass Noverta
8
4.2.1. Temperature setting
• Push and immediately release the SET key, the set point will be shown.
• Push and relase of SET key or wait for 5 sec. to return to the normal view.
Change of setpoint
• Push the SET key for more than 2 sec and release, then push the SET key again.
• Setpoint value will be displayed and tthe ”°C” LED starts blinking.
• To change the value push UP or DOWN key.
• To memorise the new value, push SET key three times or wait for 10 sec.
4.2.2. Manual defrost
Push the DEFROST button for more than 2 sec. to start defrosting.
4.2.3. The hidden menu
The hidden menu includes all the parameters of the instrument.
To enter the hidden menu
• Press the SET+DOWN buttons simultaniously for 3 sec. (°C or °F starts blinking)
• Release the buttons. Press again SET+DOWN for more than 7 secs. The L2 label will be displayed
immediately followed from HY parameter.
You are now in the hidden menu
• Select the required parameter
• Press SET key to display its value.
• Use UP or DOWN button to change the value.
• Press SET to store the new value and move to the following parameter.
To exit, press SET+UP or wait for 15 sec. without pressing any key.
If there are no parameters in ”L1”, after 3 sec. the ”nP” label will be displayed. Keep the keys pushed till
the ”L2” message will be dispalyed.
The previous set value will be stored even if the programming mode is exited by waiting for the time-out
to expire.
Move parameters from the hidden menu to the fi rst level and viceversa.
Each parameter present in the hidden menu can be removed or put into the user level (Fist level) by
pressing SET+DOWN. If the parameter is visible also in user manu, the decimal poist will lit in the hidden
menu.
4.2.4. Locking and locking of the keyboard
• To lock the keyboard, keep UP+DOWN pressed more than 3 secs.
• The OFF label will be diaplayed and the keyboard will be locked. If any button is pressed more than 3
secs, the OFF message will be dispalyed.
• To unlock, keep UP and DOWN buttons pressed together for more than 3 secs till the ”ON” message
will be dispalyed